My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1900 52ND ST SE 2018-01-02 MF Import
>
Address Records
>
52ND ST SE
>
1900
>
1900 52ND ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 11:08:57 AM
Creation date
3/31/2017 4:05:45 PM
Metadata
Fields
Template:
Address Document
Street Name
52ND ST SE
Street Number
1900
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
;iiL CASE NO. <br />ADDRESS <br />"gcciric r•o•mOitmert conditions (auplicable when checked) <br />I•lotc:: All. required repairs must be completed in a professional manner. <br />VC25 L/ Install durable plastic laminate or equal kitchen counter top and back splash after <br />first replacing any damaged or rotted underlay. <br />VC26 rinstall at least four 8"x14" galvanized hardwa:-e cloth screened crawl space area vents <br />of 4" mesh (one near each corner) to adequately vent crawl space area. <br />N6te --1Te—ta1 louvered nai.L on vents are not acceptable. <br />VC27 Install an acceptable vapor barrier ground cover over entire crawl space area. <br />VC 28 Crawl space shall be graded and sloped to prevent ponding of seepag:. water. Install <br />drain the in gravel bed connected to suitable outfall to provide positive druinage <br />away from dwrglling. Cover entire crawl space with acceptable vapor barrier. <br />VC?y f In::tall. 1/8" screened hooded roof or 1/8" screened louver gable vents to provide <br />positive cross ventilation of attic space. <br />V(30 / 1=tul.l waterproof wainscoting at L tub recess fce:t high 0 shower stall to <br />full. height of wall. <br />VC31 L Submit evidence that the leased L gas furnace burner Q hot water tunk has becri <br />purchased from the utility company or has been replaced with new equipment and is now <br />part of the realty. (Leased equipment not acceptable.) <br />VC32 Install new gas or electric gallon water heater with 3/4" non-adjustable tempera- <br />ture and pressure relief valve with discharge line to outside or interior drain. <br />Leased equipment not acceptable. <br />VC33 L Install a new forced air, wall, baseboard or other heating system adequate to heat all <br />finished rooms to 700 Fahrenheit. Submit heat loss calculations and installation plan <br />for approval prior to installation. Space or room heaters are not acceptable in <br />dwellings of this type. If electric heat is installed, adequate wiring and service <br />panel are required to meet minimum housing standards of authority in jurisdiction. <br />VC34 Remove deteriorated accessory structures as follows: <br />VC35 U Sund and refinish hardwrood floors in the foilotring rooms: <br />Ya:inted fir floors may be repainted. NOTE: The installation of carpetinG and r:urii.i.ori <br />acceptable alternate method (fl <br />meeting uM-44b standards in these areas is an <br />satisfying this condition. <br />VC36 L7 Insta.11 a solid (concrete) (asphaltic) driveway apron from the property line to the <br />street pavement, per standards of local authority. <br />VC37 L Install a solid (concrete) (asphaltic) drivewray from garage to front property line <br />per minimum property standards. Minimum width - 10 feet. <br />VC38 0 0 Replace Q Repair garage door to function properly. <br />VC39 L7 CI (a) The FHA value is based on a lot size of <br />C7 (b) Submit copy of correct legal description including lot dimensions. <br />VC40 L% L7 (a) Since a portion of the land offered as security is deemed to be ineligible <br />excess land, the Deed of Trust or Mortgage shall cover only the following <br />parcel which is eligible: <br />L/ (b) The portion of land to be excluded consists of: <br />VC41 U Submit evidence from the local authorities having jurisdiction that the su <br />property has been connected to theL7 public sanitary sewer system, L7 Public <br />water system. <br />VC42 L7 All special assessments for utilities and/or street improvements, either completed <br />or in the process of being completed, sha:Ll. be paid in full and evidence of payment• <br />submitted to this office when mortgage papers are presented for insurance. <br />
The URL can be used to link to this page
Your browser does not support the video tag.