My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2401 55TH ST SW 2016-01-01 MF Import
>
Address Records
>
55TH ST SW
>
2401
>
2401 55TH ST SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2017 2:36:59 PM
Creation date
3/31/2017 4:34:07 PM
Metadata
Fields
Template:
Address Document
Street Name
55TH ST SW
Street Number
2401
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br />October 4, 1993 <br />�. ,-. <br />�UBC/L K/O«X5 <br />Mr. Steve 1'homas <br />Thomas/Bordewick Architects <br />2630-116th Avenue Northeast <br />Bellevue, Washington 98004 <br />RE: Owner: Tony Holganza <br />Job Address: Lot 68 Division 2 Powder Mill Highlands <br />Plan Check No: B-42026 <br />Deaz Mr. Thomas: <br />In response to your application for a construc6on permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only, additional revisions or addidons may be <br />required by other de�artmcnts (such as Utilities, Planning or Fire). All references refer to the <br />1991 Uniform Buildmg Code, as amended by the State of Washington and/or Washington <br />State Energy Code 1991, 2nd Edidon, unless stated otherwise. <br />. ✓1. <br />/u�`o�/. <br />/; i <br />Please provide a signed azchitect's stamp on each sheet of the drawings. <br />WAC 308-12-081. <br />Please note that the stamp is required, as this building is over 4,000 square feet. <br />RCW 18.08.410. <br />The 4z12 floor beams (both center support and support under the guost bedrooms) aze <br />over stressed. <br />My calculations indicate failure under horizontal shear conditions. <br />Please provide engineering calculadonstojusdfy the proposed beam size. <br />The 4x4 posts supporting the floor beams require a positive mechanical tie to their <br />footings. <br />An example of a positive mechanical He would be a simpson PB44 post base. <br />Many places in the roof framing require engineering calculadons to justify beam and <br />header specs and truss connections. <br />Piease provide engineering calculations for the following: <br />Gazage Door Headers <br />Headers supporting hip master or girder trusses <br />Hip/girder truss connections shear wall truss blocking <br />CIN OF EVEREI'T• 3200 Cedar Street • Everett, WA 98201 •(206) 259-8800 • Fax (206) 259-8882 �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.