My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2401 55TH ST SW 2016-01-01 MF Import
>
Address Records
>
55TH ST SW
>
2401
>
2401 55TH ST SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2017 2:36:59 PM
Creation date
3/31/2017 4:34:07 PM
Metadata
Fields
Template:
Address Document
Street Name
55TH ST SW
Street Number
2401
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check No. B-4�026 <br />October 4, 1993 <br />Page Two of Two <br />� <br />� <br />v 5. The master bedroom !tl escape window must be 5.7 squaze feet minimum in size, with a <br />clear height of 24 inches minimum and a clear width of 20 inches minimum. <br />V 6. Smoke deG�tors must be provided in the hallway outside sleeping rooms. Due to the <br />length of the hallway one detector is required outside master bedroom Nl and one outside <br />bedrooms N3 and N4. '' <br />It appears that family �•oom is to be used as a sleeping room for a disdbled person, <br />therefor a smoke detector is requir.ed within this room. <br />� �(j(ii�i �/. Please indicate ezhaust fan sizes and the �+hole house fan (or fans) loca6on (s). <br />The whole house fan must be sized per Sec6on 302.2.2 VIAQ Code. My calculaticns <br />indicate a minimum fan size of approximately 170 CFM and a maximum size of <br />; approximately 240 CFM. Due to the probable size of a single fan and the length of the <br />house, two separate but interconnected fans may be a better soluflon for exhaushng stale <br />air from the house. <br />/�8. The planning Department has approved the plans however, a notation was made on the <br />site plan indica6ng that a maximum 18-inch roof overhang is allowed within the 7.5 foot <br />south side yazd building seWack. � <br />The plans indicate a typical overhang of ± 30 inches. <br />Please wntact Mike Palacios in the Planning Department (259-8731) for clarification. <br />In order for the processing of your application ko conrinue, it will be necessary to provide the <br />Building Division with two complete new sets of drawings reflecting the correcUons requested. <br />I Upon resubmittal of the drawings, your application will be given priority and plan review <br />� recommence. <br />; <br />! All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />that the proposed structare will be constructed in compliance with all adopted codes. <br />Since � <br />� ' l� � <br />fr . McF 1 <br />; Associate Engineer/Building <br />15M:cg/octplek.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.