My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4926 27TH AVE W 2018-01-02 MF Import
>
Address Records
>
27TH AVE W
>
4926
>
4926 27TH AVE W 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2021 9:52:07 AM
Creation date
4/1/2017 2:17:01 PM
Metadata
Fields
Template:
Address Document
Street Name
27TH AVE W
Street Number
4926
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Address or site ID: <br />1997 WSEC`Residential°C1iecIlist pa e4'" <br />FINAL PHASE <br />Corn fiance Required ✓ <br />Ina ection Approved J <br />0 <br />0 <br />30. Envelope floors shall be insulated without compression with support:5 24" o.c. to: R- <br />0 <br />0 <br />31. Non -vaulted, attic ceilings shall be insulated without compression to: R- <br />0 <br />0 <br />32. Doors shall meet U-values as per the Door Schedule & Prescriptive Option (or as calculated per Chap. <br />0 <br />Q <br />4 or 5 Qualification). <br />T. Exposed foam insulation shall comply as follows (5.502.2.4.7): ( ' <br />or flashing, or other suitable material that expands below grade. <br />a) Protected with metal plastic <br />b Insulation is approved for sub -grade, exterior use and properly installed. <br />0 <br />0 <br />34. Airflow between fresh air ports and whole -house fan ensured by undercut doors/grilles. <br />0 <br />0 <br />35. Loosefill insulation okay if (5.502.1.4.5): <br />a) Maximum ceiling slope not >3 in 12. <br />b z 30" clearance distance from top of bottom chord to underside of roof sheathin at roof ridge. <br />0 <br />0 <br />36. 6 mil black polyethylene ground cover shall be lapped 12 at joints & extend to foundation wall. <br />0 <br />0 <br />37. Clearances shall meet listed minimums between insulation and (S 502.4.3): <br />a Chimney b Non -IC rated recessed lights: 12" to combustibles, 3" to insulation <br />0 <br />0 <br />38. Attic hatch shall be insulated to required ceiling R-value and weatherstripped (5.502.1.4.4). <br />0 <br />0 <br />39. Attic access shall have wood dam or equivalent to retain loose fill insulation in attic (5.502.1.4.4). <br />0 <br />0 <br />40. All exterior doors (except 20 minute doors) shall be weatherstripped (5.502.4.3). <br />0 <br />0 <br />41. Service hot & cold water piping in unconditioned spaces shall be insulated to R-3 (5.503.1I). <br />0 <br />0 <br />42. Service recirculating hot water piping in unconditioned spaces shall be insulated to Table 5-12. <br />0 <br />0 <br />43. Heat pump thermostat shall have programmable capability (S. 503.3.5). <br />0 <br />0 <br />44. Thermostat provided for each HVAC system with range of 55-75° F (heating) (S 503.8.1.1). <br />0 <br />0 <br />45. Readily accessible, automatic or manual means provided to restrict or shut-off Heating input to each <br />0 <br />0 <br />zone during periods not requiring heat S 503.8.3.1). <br />46. Mechanical ventilation system shall have proper timers, and/or switches (VIAQ, S 302.3). <br />0 <br />0 <br />47. Mechanical ventilation ducts shall have R-4 insulation in unconditioned spaces (VIAQ< S. 302.5). <br />0 <br />0 <br />48. Mechanical ventilation supply ducts in conditioned spaces shall have R4 insulation. <br />0 <br />0 <br />49. Supply ducts shall have volume dampers, or the equivalent, to balance system (S. 50.6). <br />0 <br />0 <br />50. Supply and return as ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br />0 <br />0 <br />51. HVAC plenums, supply, & return air ducts shall have R-8 insulation. ( Prescriptive and Chapter 5) <br />.0 <br />0 <br />52. Hot water heater(s) shall have (5.504.3, 504.4): <br />�y <br />a) Separate power, or gas shut-off c) Temperature setting 51200 F. <br />b 1987 NAECA Label on tank d Non -compressible R-10 pad unheated spaces, electric only) <br />0 <br />0 <br />53. Swimming pools (5.504.5) shall have: <br />a Accessible ONI OFF switch (pum12, heater b Pool cover c Piping insulated to S. 503.11 <br />0 <br />0 <br />54. All fireplaces (VIAQ, 5.402.3) shall have: <br />a) 6 square inch combustion air supply duct w/ accessible damper directly connected to the fire <br />ON <br />box <br />State Certified Fireplaces may size duct according to manufacturers instructions) <br />(Washington <br />b) Tight -fitting lass or metal doors c Tight -fitting flue damper <br />0 0 55. Solid fuel burning appliance(s) (VIAQ, S. 402.2) shall have: <br />b Outside combustion air source directly connected to the fire box <br />a) Tight -fitting lass or metal doors <br />WSEC Final Phase Requirements: <br />Date: <br />Inspected by- �e <br />L <br />
The URL can be used to link to this page
Your browser does not support the video tag.