Plan Check No. 90/z6105 <br />Page two of th e'J- <br />r <br />7. Restroom facilities for the physically bandi.:apped should be provid�i <br />as set forth in Section 511 as follows: <br />a. Where toilet facilities are provided on any floor where access by <br />h&N `( the physically handicapped is required by Table No. 33-A, at least <br />\ one toilet facility for each sex or a separate facility usable by <br />either sex should comply with Section 511(a). <br />QJ b. All doorways leading to toilet rooms should have an unobstructed <br />width of not less than 32 inches. <br />c. A 44-inch clearance on each side of doors providing access to toilet <br />rooms. No more than one door may encroach into the 44-inch space. <br />d. A clear circular space of 60-inch diameter within the toilet room. <br />Doors may encroach into this space by not more thean 12 inches. <br />e. A 42-inch wide by 48-inch long clear space in front of at least one <br />water .closet stool. A 32 (34)-inch clar width entry to the <br />compartment should be provided. Water closet compartment door <br />should not encroach into the required space in front of the water <br />closet. <br />f. Grab bars should be parallel to and 33 to 36 inches above floor. <br />Side grab bars should be 42 inches long with the front end <br />positioned 24 inches in front of the water closet stool. Grab bars <br />at back should be at least 24 inches long for room installations and <br />36 inches long where the water closet is installed in a stall. Grab <br />bar diameters should not be less than 1-1/4 nor more than 1-1/2 <br />inches providing a 1-1/2 inch clearance between the grab bars and <br />adjacent surface. (Grab bars are not required in Group R, Division <br />1 apartment 'douses). <br />gC �When it can be established that the facilities are usable by a <br />(.! person in a wheelchair, dimensions other than those above should be <br />acceptable. <br />h. A clear space 30 inches wide, 29 inches high and 17 inches in depth <br />should be provided under each lavatory. <br />i. Bottom of at least one mirror should be within 40 inches of the <br />floor. <br />J. Towel fixtures should be accessible to the physically handicapped <br />placed within 40 inches of the floor. <br />