My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 19TH AVE SE COSTCO FUEL STATION 2016-01-01 MF Import
>
Address Records
>
19TH AVE SE
>
10200
>
COSTCO FUEL STATION
>
10200 19TH AVE SE COSTCO FUEL STATION 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2017 9:21:02 AM
Creation date
4/2/2017 9:18:16 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10200
Tenant Name
COSTCO FUEL STATION
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEOTECHNICAL ENGINEERING STUDY <br /> Costco Wholesale <br /> c/o Bargha��sen Consulting Engineers E-8556 <br /> January 13, 1999 Page 5 <br /> The existing fill and �iative soils are moisture sensitive, and will becume unstable when <br /> exposed to excessive moisture. Compaction and gradinc� of these soils will be difficuli if the 'I <br /> moisture content is above optimum. During dry weather, the existing silty sand soils can be , <br /> considered for use as structural fill, provided the moisture content of the soil is at or near <br /> optimum at the time of placement. At the time of our exploration, the existing fill and native <br /> silty sand soils were generally above the optimum moisture content, and would require I <br /> moisture i:onditioning before placement. Fill for use during wet weather should consist of a <br /> fairly well graded granular material having a maximum size of three inches and no more than <br /> five percent fines passing the No. 200 sieve based on the minus 3/4-inch fraction. <br /> Structural fill is defined as compacted fill placed under foundations, roadways, slabs, <br /> pavements, or other load-bearing areas. Structural fill under slabs and footings should be <br /> placed in horizontal lifts not exceeding twelve (12) inches in loose thickness and compacted <br /> to a minimum of 90 percent of its laboratory maximum dry density. The maximum dry density <br /> showd be determi�ied in accordance with ASTM Test Designation D-i 557 (Modified Proctor). <br /> The fill materials should be placed at or near the optimum moisture content. Fill under <br /> pavements and walks should also be placed in horizontal lifts and compacted to 90 percent <br /> of maximum density except for the top twelve (12) inches which should be compacted to 95 <br /> percent of maximum density. <br /> Foundations <br /> In our opinion, the proposed fueling canopy can be supported on a conventional spread and <br /> continuous footing foundation bearing on the competent native soils or on structural fill. <br /> Based on the subsurface information obtained at the site, the competent native soils should <br /> be encountered below a depth of approximately four feet. As mentioned previously, the <br /> existing fill can be considered for use as structural fill, provided the soil can be compacted to <br /> the specifications of structural fill. <br /> Ennh Consultonts, lnc. <br /> 1� <br />
The URL can be used to link to this page
Your browser does not support the video tag.