Laserfiche WebLink
, � � <br /> Plan Check q53279 <br /> May 15, 1997 <br /> Page 2 of 2 <br /> 6. Appliances installed in garages shall be suitably guarded against mer_hanical damage by being <br /> installed behind protective barriers or by being elevated or located out of the normal path of <br /> vehicles (308 UMC). <br /> 7. Provide additional braced wali panel on garage wall and master beclroom wall. Braced wall <br /> panels are required at each end of each braced wall line. <br /> 8. Provide wheel stop in garage to protect washer and dryer. I <br /> Prepare a response letter showing where each item in this correction letter is addressed on th� plan I <br /> set. <br /> Upon resubmital of the drawings, your application will be given priority and plan review will <br /> commence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br /> the proposed struct�re will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ���_ <br /> eff Heilman <br /> Development Technician <br /> �H:�a:N�n��q <br /> — –--- -- ..— . 1 <br />