Laserfiche WebLink
r <br /> Ltr. A. Clark <br /> September 11, 2007 <br /> Page 2 <br /> 7. IBC 1007.1 requires two accessible means of egress from each floor. Section 1007.2 <br /> allows stairways or elevators. Section 1007.3 and 1007.4 require areas of refuge. <br /> Areas of refuge must comply with Section 1007.6. <br /> 8. ANSI A117.1 Section 505.10 requires handrail extensions at accessiUle stairways. <br /> 9. The accessible parking sign is required to be 5'-0" minimum above the parking floor <br /> measured to the Uottom of d�e sign. ANSI A117.1, 502.7. <br /> Please prepare a response letter showing where each item in this correction letter is a�dressed <br /> on the plan set. <br /> Upon resubmittal of thc drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required suUmittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed.swcture will be constructed in compliance with all adopted codes. <br /> Sincercly, <br /> ;��v;- . � � <br /> Steve Miller �' <br /> Associate �ngineer <br /> �UP-UI PL\fA\ISI H,�nI.11iN Im1G9-oln(I_1:s-Ivu�n\•I:sl:� <br /> y <br />