My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12728 19TH AVE SE BASE FILE 2016-01-01 MF Import
>
Address Records
>
19TH AVE SE
>
12728
>
BASE FILE
>
12728 19TH AVE SE BASE FILE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2017 8:01:01 AM
Creation date
4/2/2017 2:12:36 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12728
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
294
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � . <br /> RESUBMITT^' ZESPONSE LETTER: Builders Investment Group New Building —Mechanical <br /> Page 2 <br /> Respor.se: Building and mechanical design was reviewed together�Hith Gaffney <br /> Construction and Tony Finsland. It was determined that wails surrounding the <br /> Core (Lobby, Hall, Utility Room and ResVooms) on each floor are rated such that <br /> ducts �an pass through without fre-smoke dampers. Ducts from rooftop unit <br /> RTU-7 which pass from ceiling of 3'"floor through 3`° and 2n° floors down tc <br /> ceiling of 181 floor will require a one-hour rated chase from 3'"floor ceiiing to top <br /> of floor between 1°`and 2nd floors. A fire-smoke damper is require�!where each <br /> main duct enters at top of chase, and where they exit at bottom of�:hase, and <br /> in addition wherever a duct branch exits the chase. Restroom exhaust ducts <br /> need no fire-smoke or fire dampers. Please refer to Tony Finsiand for a detailed <br /> explanatio� of why the Core walls do not need to be rated. <br /> Two pages from 2001 Fire Resistance Directory and six pages fi•om <br /> Gypsum Constructior. Handbook given me by Gaffney Constructiori show <br /> options for rated chase construction. Please let me know if this fulfi►Is require- <br /> ments. <br /> 3. The support of the seven new rooftop units requires review and stamped structural verification <br /> by a Washington State licensed professional engineer. If required, modifications to the struc- <br /> tural roof framing should also be submitted and wet-stamped by the engineer. For reference, <br /> the number and weights of the rooftop units (RTU) shown on the structural roof framing plan <br /> should coincide with the rooftop unit schedule on sheet M-3. <br /> Response: CanAm drawing JE3 of 5 attached with original submittal shows all roof <br /> trusses,joists and girders and in addition location of each rocftop unit with <br /> weight shown. Selected portions of CanAms structural calculations for each <br /> truss,joist and girder affected by one or more rooftop unit are attached. Cover <br /> page for calculations carries wet stamp of CanAm's structural engineer. The <br /> following rooftop units affect the following structural members: <br /> RTU-1: TJ55 and J55. <br /> RTU-2: J39 and J56. <br /> RTU-3: J59 and TJ51. <br /> RTU-4: J35 and J54. <br /> RTU-5: TJ49 and J49. <br /> RTU-6: TJ49 and J49. <br /> RTU-7: J43, TJ44 and G26. <br /> Sheet M-4 rooftop unit numbers were corrected to properly ceincide with <br /> schedule on sheet M-3. <br /> 4. Economizers either are required unless documentation is provided that demonstrates that <br /> economizers are not required, per WSEC table 11-1, or per WSEC section 1423 economizers. <br /> RTU-1, -3, -4 and -6 do not have economizer note referenced on the rooftop unit schedule on <br /> sheet M-3. <br /> Response: All rooftop units will have economizer and schedule was updated to <br /> include economizer infa for all units. <br /> Thanks, <br /> Bengt /��( <br /> Bengt-Olov Nordensson/SVVEDE HVAC, Inc. <br /> Celi: 425.508.8984 <br /> E-ma�l: swedehvac@hotmail.com � <br /> �/� / <br /> �� <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.