Laserfiche WebLink
Page 2 <br />October 2.1, 1975 <br />5. An occupant load sign is required. Section 3301(j) <br />6. All doors shall swing in the direction of egress and <br />be equipped with panic hardware. Section 3303(b) & <br />3316(a). <br />7. Illuminated exit signs shall be furnished at all exit <br />doors. Said exit signs shall be supplied with two <br />separate sources of power. <br />8. Shower walls shall be finished to a height of not less <br />than 6 feet as set forth in item 3 above. Section <br />1711(d) . <br />9. Shower doors and panels shall be constructed of shatter <br />proof resistant materials and swing outwardly. Section <br />1711(e) <br />10. Fireplace drawings and details shall be submitted for <br />approval prior to construction and be constructed in <br />complete accordance of Chapter 37. <br />11. All glass and glazing shall be installed in complete <br />compliance with the Washington State glass and.glazing <br />code and chapter 54 of the U.B.C. <br />12. The dropped one -hour fire -resistive ceiling as indicated <br />on the plan shall extend throughout the building and <br />protect all portions of the roof and roof framing <br />members. Section 2101 <br />13. The fire resistive rating in all columns and exterior <br />walls shall be maintained where they pass through attic <br />areas. Section 4304 <br />14. Only non combustible materials (approved pressure <br />treated fir retardant wood at walls) can be used in <br />type IV buildings. <br />15. Facilities for the handicapped shall be provided in <br />compliance with AP]SI.1-1961 as adopted by the State of <br />Washington in the State Building Code. A detailed <br />floor.• plan will be necessary to show complaince. <br />16. Sanitary facilities shall be provided as follows in <br />compliance with appendix C of the U.P.C. ammended: <br />Men <br />3 water. closets <br />3 urinals <br />3 lavatories <br />Women <br />4 water closets <br />3 lavatories <br />a detailed floor plan showing conplaince. <br />