Laserfiche WebLink
Oil Express Inc. <br />April 4, ?001 <br />Page 2 of? <br />Cnnstruction (cont'd) <br />3) Fire blocking should be shown in the walls in line with the dropped ceilings. Section 708.2.1 <br />d) A guardrail should be orovided where the stairs ro the meuanine pass by the office window. Section �09.1 <br />5) Glazing wirh the top edee Y or less above the tloor and within 3d" of either vertical edge oFa door (in a closed <br />position) should be labeled as safety blazi;:� on the plans. Section 240ti.4 <br />6) Fire blocking should be shown in the walls in line �vith the dropped ceilinos. Section 708.?.I <br />7) Insulation requirements (shell) should be noted for the lube bay areas. If it is to be a non-or semi-heated space, <br />the followin� criteria must be followed per Section 1310.3: <br />a) The installed hcating equipment output should be behveen 3 and 8 Btu. <br />b) Fleating should be controlled by a thermostat mounted not lower dian the heatin� unit and be capable of <br />preventing heating abeve 44 degrces. <br />c) A minimum of R-I t roof insulation should be shown (wood roof option). <br />Accessibility <br />I) Solid risers should be shown on the stairs. Section I 106.9.2 <br />2) Details for the size, signage, and striping of the accessible p�rkir.g stall�, access isles. and accessible route of <br />travel to the public way should be provided. Sections I 107.3, 1 103.2.? & I 103."_'.4.1 <br />3) At least one accessible parking stall should be van accessible which will require a dedicated 8' wide access <br />aisle. Section 1107.1.6 <br />d) The exposed hot warer supply and drain under the lavatories should be shown �uarded or wrapped to prevert <br />contact. Section I 106.1 L7.d <br />�) Thc grab bars behind the roilets should estend at least I"? inches beyond the center of the water closet to���ard <br />the side wall, and at least 2d inches to�vard the open side of the �varer closet. Secdon I 106.1 L�.3 <br />Prepare a response letter showine where each item in this correction letter is addressed on the plan set. <br />Upon resubmi,sion of [he dra�vings, your application will be given priority and plan review will recommence. <br />All rcquired submittals shall be of s�fficient detail and contain sufticient infonnation [o ensure that the proposed <br />structure �cill be constructed in cnmpliance with all adopted codes. <br />Sincerch. <br />/ �� <br />To� ^ Lee <br />Plans F�aminer <br />ti::11.inJs:n�.\1�0!�1� 11[I�_ -fbi�lU3�111 I.Juc <br />