2. The high piled combustible stock should be identified and classified by category and <br />shown on the plans per Table 81-A, UFC. All requirements for smoke venting, <br />curtain boards, smoke alarms, rack design and construction etc. should be indicated <br />and detailed on the plans per UFC Article 81 and UBC Chapter 22, Division VI. <br />Note that if any items are to be submitted under a separate permit, they should be <br />listed as deferred submittals on the cover sheet. Section 106.3.4.2 <br />3. Based on an occupant load of 200, four female -use water closets, and a total of three <br />drinking fountains are required on -site. Table 29-A, Washington State Amendments <br />Construction <br />The one-way glass in office 204 should be specified to be safety glass per Section <br />2406.4, item 8, or a guardrail should be provided per Section 509 where the stairwa'., <br />passes the glazing. <br />2. The shaft in detail 2/A-5.2 should be specified to have the gypsum wallbo-al on both <br />sides of the metal studs. Table 7-B <br />3. It should be specified that the roof insulation, including vapor barrier shall have a <br />maximum flame spread rating of 25 and a smoke density not to exceed 450. Section <br />707.3 <br />Exiting <br />An exit sign should be shown at Door #116. Section 1013.1 <br />Accessibility 1995'Washington State 9Qeguhuions for Barrier -Free Design <br />1. The ADA parking sign on Detail 15/SD-2 should be shown as 3'-5' high centered at <br />the head of the space and bearing the words, "State Disabled Parking Permit <br />Required." Section 1107.3 <br />2. Stairway treads (Detail 3/A-9.1) should have rounded non -slip nosings shown which <br />project less than 1-1/2". <br />Energy. 1995 Washington State Non -Residential Energy Code <br />The plan notes should indicate the chosen energy code compliance option for the <br />building envelope, as well as calculations or documentation provided. Section <br />1141.2 <br />