G� <br />C� <br />� <br />'r'UBLIC WORKS PERMIT COMMENTS <br />Connect side sewer oer City Standard #601. <br />Connect side sewer per City Standard #'s 601, 602, 604. <br />Connect all rooftop downspouts to the side sewer. <br />Connect rooftop downspouts to the drainage system provided for this iot. <br />Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br />Manuat 3-2.6.2. The approximale size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />The contractor must meet with lhe Public Works Inspector to discuss potenliai drainage routing prior to <br />beginning the project. <br />10. J Install erosion conlrol measures as determined by lhe Public Works inspector, such as silt fence, straw <br />bales, swales, or erosion biankets. <br />Inslall erosion conirol measures per Cily o( Everetl Slandards for small parcels <br />Remove erosion control measures upon completion of lhe project prior to final approval of the permit. <br />_-- �---------- ---- -- --- - ---- - -__ --- - <br />13) All excavated material from (oun�,,tion, sidewalk and driveways shall be hauled to an approved, <br />� permifted sile. No wasling of materiai is allowed on lhis building lot. <br />No dirt, mud, rocks or debris lo be tracked onto roadway. <br />No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br />pedestrian travel. <br />Adjust water meter box 1" above sidewalk grade. <br />Remove and replace curb, gutler and sidewalk as per Cily o( Everett Standard Plan #'s 305A & 306 on <br />this proposal's frontage as directed by the Public Works Inspector (i.e. all unused driveways and any <br />broken or damac�ed area must be replaced). <br />Insta!I a Type I concrele driveway per Cily of Everelt Standard #307. <br />Pave driveway from the front property line out to the street paving. <br />20. Contact the _ <br />sev�er services. <br />21. <br />22. <br />23. <br />Water Districl (or connecting provisions for this building's water and <br />A catcli basin as per City Standard Plan i1402 with a c�as trap per Standard Plan #410 is required for lhe <br />parking area. <br />If a sewer pump system is to be installed, the pressure line must discharge into a privale manhole, then <br />gravity flow scross lhe public right-of-way. <br />A sprinkler syslem is required for this building in compliance with the requirements of NFDA Standards <br />13D. <br />PWCommenis <br />:' � � <br />