My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11033 7TH AVE SE 2018-01-02 MF Import
>
Address Records
>
7TH AVE SE
>
11033
>
11033 7TH AVE SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 9:13:12 AM
Creation date
4/3/2017 12:52:02 PM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
11033
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2004 <br />Nonresidential Energy Code Co 'ance Form <br />Forms <br />Glazing <br />Proposed SHGC <br />Target SHGC <br />List components by assembly ID & page ll <br />SHGC' x Area (A) SHGC x A <br />SHGC x Area A = SHGC x A <br />ID: <br />0.400 972.0 388.8 <br />Glazing % Electric Resist. Other Heating <br />ID: <br />c <br />ID: <br />0-30% 0.4 0.45 <br />f0 <br />ID: <br />>30-45% not allowed 0.4 <br />a <br />ID: <br />ID: <br />'Note: Manufacturer's SC may be used in lieu of SHGC. <br />Totals <br />972. 0 <br />389.8 <br />Totals <br />For compliance: Proposed total SHGC x A shall not exceed Target total SHGC x A <br />NOTE: Since 1997 SHGC compliance for vertical and overhead glazing is allowed to be calculated together. <br />II the total amount of glazing area as a Y of gmas exterior well area (calculated on ENV -SUM I) exceeds the maximum allowed in Table 13-1, <br />Then this calculation must be Submitted Use the resulting areas in the Target UA and SHGC calculations above. <br />Glazing Area <br />Opaque Area <br />Proposed Areas: Numbered values are used in calculations below. <br />Roofs over Attics Other Roofs Welts <br />OG= <br />OG= <br />IVG= 972.0 <br />5550.0 <br />13221.0 <br />Gross Exterior Wall <br />Max Glazing Area <br />Maximum Target <br />Area <br />(Table 13-1) <br />Glazing Area <br />6836.0 <br />X 3e. e+a <br />T ADO = <br />1667.2 <br />Target OG Area In Roofs over Attics Tang, <br />r( Max OG Remaining <br />14a7.2 <br />Q 1a95er <br />= <br />1aa7.2 _- <br />_—> <br />1447.2 <br />--X <br />Proposed Opaque Ama <br />} <br />Proposed OG Area <br />Roots over Attics <br />Other Roots <br />5550.0 <br />�- <br />— <br />Nato: <br />OG = overhead glazing <br />VG = vertical glazing <br />Area in Other Roofs <br />Target VG Area For Target OG's, the <br />972 0 lesser values are <br />it. -ear <br />usetl both hera and <br />below. <br />l'argm Opaque Area <br />5550.0 <br />Proposed Onpque Area Proposed VG Area Target VG Area Target Opaque Area <br />Walls 3221.0 -H 972.0 — 971.0 = 3221.0 Target Arcaa OK <br />Note: If there is more than one type of wall, the Target VG Area may be distributed among them, and separate Target Opaque Areas found. <br />If the Target Areas for Opaque Walls listed on the front must equal the total calculated here. <br />Target values In shaded boxes are used In the applicable Target UA calculations on the front. <br />Target VG Area and Total Target OG Area are also used In the applicable Target SHGC calculations above. <br />045 <br />
The URL can be used to link to this page
Your browser does not support the video tag.