Laserfiche WebLink
2004 V' -hineton Stale Nonresidential Energy Code Cc-liance Form <br />2004 Wasmngton State Nmresidentnt Energy Gods Compliance Forms Revised May 2006 <br />Project Info Project Address 711 1'2ut STREET SOUTHEAST Date 6/9/2006 <br />FRESH CONNECTIONS PRODUCE For Building Department Use <br />EVERETT, WA 90208 <br />Applicant Name: PACIF11 CENTERS INC, / ED O'SULLIVAV <br />Applicant Address: 6533 SEAVIE14 NW APH2A, SEATTLE, WA 98117 <br />Applicant Phone: 206-783-1499 <br />t <br />tDescription I❑ New Building ❑ Addition [J Alteration 0PlansIncluded <br />Refer to WSEC Section 1513 for controls and commissioning requirements. <br />Prescriptive * Lighting Power Allowance Q Systems Analysis <br />Compliance Option (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) <br />Alteration Exceptions ❑ No changes are being made to the Ilghtinq <br />(check appropriate box -sec. 1132.3) ❑ Less than 60% of the fixtures new, installed vatage not increased, & space use not changed. <br />A,T....:........ An..A T ioh }inn Wa}}��o (Tn+arinrl <br />,Location <br />(floor/room no.) <br />Occupancy Description <br />Allowed <br />Watts per f? " <br />Area in fly <br />Allowed x Area <br />SALES/100 <br />RETAIL BALES <br />1.50 <br />4039.0 <br />6050.5 <br />LOADING/101 <br />LOADING AREA f STORAGE <br />0.50 <br />923.0 <br />461.5 <br />OFFICE/102 <br />OFFICE <br />1.00 <br />70.0 <br />70.0 <br />RR'S/104-105 <br />RESTROOMS G CORRIDORS <br />0.90 <br />172.0 <br />137.6 <br />" From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts <br />6727.6 <br />Notes: <br />1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, <br />the default table in the NREC Technical Reference Manual may also be used <br />2. Include exit lights unless less than 5 watts par fixture. <br />Prnnncpd i.ivhtinQ Wattage (Interior) 3. List all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank. <br />Location <br />(floor/room no.) <br />Fixture Description <br />Number of <br />Fixtures <br />Watts/ <br />Fixture <br />Watts <br />Proposed <br />RAZES/100 <br />LITHONIA LOW HAY TxV <br />15 <br />250.0 <br />3750.0 <br />LOADING/101 <br />ACCULITE 'REWOTE BALLAST' Re1175NH <br />6 <br />175.0 <br />1050.0 <br />LIGHTOLIER 'CLEANLITE' <br />1 <br />32.0 <br />32.0 <br />OFFICE/102 <br />LIGHTOLIER WBAS33411 <br />1 <br />110.0 <br />110.0 <br />RR'S/104-105 <br />LIGHTDLIER MIA234 <br />70.0 <br />140.0 <br />LIGHTOLIER 'CLEAHLITE' <br />1. <br />32.0 <br />32.0 <br />To Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts <br />5114.0 <br />NA--... A I1n..,nA T ioh}inn Wa+}aon Mv}arinrl <br />Location <br />Description <br />Allowed Watts <br />per 112 or per It <br />Area in fe <br />(or If for perimeter) <br />Allowed Watts <br />x fe (or x If) <br />Covered Parking <br />(standard paint) <br />0.2 W/ft2 <br />Covered Parking <br />(reflective pafnt) <br />0.3 W/ft2 <br />Open Parking <br />0.2 W/ft2 <br />Outdoor Areas <br />0.2 W/ft2 <br />Bldg. (by lacade)' <br />0.25 W/it2 <br />Bldg. (byPerim)r <br />FA('ME 4 CANOPY LIGHTING <br />7.5W/If <br />298.0 <br />2235.0 <br />1. Choose either the facade area or the perimeter method, but not both) Total Allowed Watts <br />2235.01 <br />9e; <br />