My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11033 7TH AVE SE 2018-01-02 MF Import
>
Address Records
>
7TH AVE SE
>
11033
>
11033 7TH AVE SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 9:13:12 AM
Creation date
4/3/2017 12:52:02 PM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
11033
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. A Knox Box is required. <br />3. Premise Identification - Premises shall be clearly identified by the correct address at the <br />street entry. Buildings shall be clearly identified so as to be visible and legible from the <br />access road. Individual apartments and suites, where applicable, shall be clearly and <br />legibly identified from the access road. <br />4. PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT <br />ACCESS ROADS AND FIRE HYDRANTS SHALL BE IN SERVICE PRIOR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />5. A fire hydrant is required within 200 driving feet, but not closer than 50 feet, of every <br />structure. Location of the hydrant(s) shall be approved by the Fire Marshal. <br />6. Based upon 5,550 square feet of Type V-B, non-sprinklered construction, the fire flow <br />requirement is 2,000 gpm. <br />7. Portable Fire Protection - A portable fire extinguisher with a minimum U.L. rating of <br />2-A:10-B:C shall be provided within 75 feet of travel on all floors of each building <br />during construction and prior to occupancy. <br />8. Fire Alarm System - An approved automatic fire detection system shall be provided as <br />required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. <br />Plans for such system shall be submitted to the Fire Marshal for review and approval <br />prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department inspector, shall be performed, <br />along with a certificate of completion, prior to final acceptance of the system. <br />Fire alarm systems shall be installed according to NFPA Standard 72. Installation of <br />fire alarm components, including basic wiring, may not commence befi,--Z plans are <br />approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br />professionally rendered, in sufficient detail, and must be internally consistent. Riser <br />diagrams must match installation plans and load calculations. Components must be listed <br />and approved for use together. Changes to plans must include new drawings and <br />calculations and must be approved by the Fire Department Plan Reviewer prior to <br />installation. Fire alarm installation is subject to field inspection by a Fire Department <br />Inspector. An approved set of plans and the Building Department electrical permit must <br />be present for any installation inspection. <br />Fire alarm systems shall be installed under permit of the City of Everett Building <br />Depattment. Electrical inspections and approval are required prior to calling for <br />acceptance tests. Call (425) 257-8810 for permit information. <br />The absence of working phone lines for the alarm system 1611 be cause for <br />postponing fire department inspection and testing :and shall result in denial of <br />occupancy. 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.