My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8526 8TH AVE W 2016-01-01 MF Import
>
Address Records
>
8TH AVE W
>
8526
>
8526 8TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2017 11:53:34 PM
Creation date
4/3/2017 1:51:10 PM
Metadata
Fields
Template:
Address Document
Street Name
8TH AVE W
Street Number
8526
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
., <br />�1ay 26, 2000 <br />l <br />'UBL/f f�YO/uLs <br />Richard Russcll <br />VI'holcsalc Inc. <br />I3ox 308 <br />East Sound WA 98245 <br />Subject: O���ner. Teilefsen <br />Address: 8526 — 8'h Avc 1�1' <br />Plan Check #: B9911-018 <br />Dear Mr. Russell: <br />In response to your application for a construction permit, your plans hace bcen examined <br />and you are advised that the issuance of a pemiit is bcing H�idihcld for the rcasuns listcd <br />below. These commcnts address building issues only. Othcr departments (such as <br />Utilitics. Planning or I�ire) ma}• require additional revisions o: additions. All references <br />refer to the 1997 Uniform Building Codc, as amendcd by the Statc of �\'a�hington and/or <br />1�'ashington State Energy Codc 1997 6dition, unlcss stated othenvisc. <br />In order for the processing of your application to continue, it will be neccssary to provide <br />the Building Division with two completc new sets of drawin�s reticcting the corrections <br />requcstcd. <br />1. The pariy walls are designated to bc SW2XGWB. The shearwall schedulc on pagc <br />19 of the structural drawings contains no nailing requircmcnt for this designation, <br />which is not succeeded by a number. The GW'13 is apparendy unspecitied. UIiC <br />310.2.2 and Appcndix ] 208 requires these walls to bc of onc-hour firc-resistive <br />construction and provioe a minimum sound transmission control cocfficicnt of 50. <br />2. The shear walls at east and west end ti�alls are also designated as SW2XGWII. <br />Please providc GR'B specifications and nailing requircments. Ono-hour firc- <br />resistive conswction is required bct�i•ecn thc garage and apartmcnts per Uf3C 302. <br />3. <br />� <br />The plans should indicatc thc requirement for one-hour fire-resistive construction of <br />the enclosed stainvay walls and soffits. UAC 1003.33.9. <br />Thc plans should specif}' handrails at stainvays. <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.