Laserfiche WebLink
December 18, 1990 <br />Scate Smith <br />8920 8th Avenue W <br />Everete, Washington 98204 <br />RE: Owner: Scott Smith <br />.Iob Address 8920 8th Avenue W <br />Plan Check No. 90/26037 <br />Dear Mr. Smith: <br />everett <br />+Fr � . � �:rr,•.. <br />cnr �.x <br />everett <br />In response to your application for a construction permie, your plans have <br />been examined anA you are advised [haC Che issuance o[ a permit is being <br />vi[hheld for [he reasons lisCed below. <br />1. Site plan does not shou dimencions of axisting structure. See <br />enclosed site plan. <br />2. Proposed structure does not meet 20' minimum secoack reqrirement a[ <br />the r.or[hwest corner of addition. <br />3. R-19 lnsulation will not fit into the cavi`/ of a 2 x 4 vall. <br />4. Labe1 pinns and/o[ �etails, Indicate scale. <br />5. No floor plan provided. Indicaee the current use of room(s) <br />adjoining addition. Include interior pacdtions, windows and doors <br />oi existing rooms. <br />6. No indication of level oE insulation in ceiling. <br />7. Bearing and exterior wnll studs shall be capped viCh double top <br />plares installed to provide ove[lapping a[ corners and at <br />intersections wLth other partitions. End joints Ln double top plates <br />shall be offset at least 48 inches. <br />8. The "sou[h iraming" detail indicates cwo openings foc windows, Che <br />elevation calls out 3 vindows. Also .ae #7 aUo�ie for plarement of <br />headers. <br />