My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST ACUTE CARE TOWER 2018-01-02 MF Import
>
Address Records
>
13TH ST
>
1700
>
ACUTE CARE TOWER
>
1700 13TH ST ACUTE CARE TOWER 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2020 9:29:23 AM
Creation date
4/4/2017 10:48:37 AM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Tenant Name
ACUTE CARE TOWER
Notes
INITIAL BUILDING PERMITS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
658
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , <br /> �IRElLIFE SAFETY REPORT S41915 — Page 3 <br /> ' PROVIDENCE EVERETT MEDICAL CENTER February 05, 2008 <br /> NEW TOWER EXPANSIGN <br /> ' B. The basement level of the tower is allowed to be classified as a <br /> separate occupancy to the hospital above as the basement will be <br /> ' separated from the ground Floor by 2-hour floor construction and will <br /> not serve any health care occupants (NFPA 101). As such the code <br /> requirements for a healthcare occupancy will not apply to this level. <br /> ' The basement wili be considered a non-separated mixed occupancy <br /> containing S-1, S-2 and B occupancy areas. However, as required by <br /> NFPA 101 .18.3.7.1, the floor must be separated into two smoke zones. <br /> ' <br /> C. The lobby areas on the north side of floors G and 1 and the waiting <br /> � area in the northwest corner of Floor 2 will be separated from the <br /> neighboring I-2 areas by 2-hour fire barrier construction. These areas <br /> will 5e considered A-3 occupancies. To accommodate exiting by I-2 <br /> ' occupants through the A-3 occupancy areas the 2-hour fire barrier on <br /> floor G will be constructed as a Horizontal Exit. <br /> � II. CONSTRUCTION <br /> A. Construction Classification <br /> � The minimum construction type for tne building is Type I-B construction <br /> as permitted by IBC 403.3. This section allows Type I-A construction <br /> ' to be reduced to Type I-B when supervised sprinkler control valves and <br /> water-flov� devices are instailed on every floor. The Type I-A allowable <br /> height and area apply to this building, both of which are unlimited. <br /> � <br /> B. Minimum Fire Resistance Ratings <br /> ' 1. Exterior Walls <br /> � a) Bearing - 2-hour rating <br /> b) Non-bearing - 1-hour rating where fire separation' is 30 feet <br /> ' or less; non-rated in all other areas. <br /> 2. Interior Walls <br /> � a. Bearing — 2-hour, 1-hour where supporting roof only <br /> , � The fire separation distance is that measured from the face of the building to lhe closest interior lot <br /> � line, center of a public street, alley or public way, or to an imaginary property line between two <br /> buildings on the same lot. <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.