HIGHLIGHTS AND CHANGES <br /> Building - <br /> ' The Pire resistive protection af columns and beams within <br /> assemblies requires individual ;,:otection unless tested as part oP <br /> the assembly. <br /> " Suspended ceiling seismic bracing requirement is enforced. <br /> " Fire resistive assembly details are required on plans (including <br /> Test Number). <br /> " Stair sections are required showing rise, run and headroom. <br /> (Stair run is not synonymous with tread and headroom is now a <br /> minimum of 6 feet 8 inches.) <br /> ' Sections and details are to be related to th� specific conditions - <br /> "Typicals" are not acceptable. <br /> Plmb/Mech - <br /> • Floor drain primers are required. <br /> " Gas piping is not to be concealed unless access panels are provided. <br /> * Roof access (permanent) is required for mechanical equipment. <br /> * Dryer vent maximum length is 14 feet with two 90o elbows. <br /> " Sheet metal screws are required at the Joints of prefabricated <br /> metal chimneys. <br /> " Barrier free water closet height is 17 to 19 inches. <br /> " Laundr; rooms (including closets) require a fan. <br /> Electrical - <br /> ' Wiring in noi� dwellings is required to be in conduit. <br /> State electrical plans review is required Por educational, <br /> institutlonal and health or personal care occupancies prior to <br /> permit issuance. <br /> 5378H <br /> 7/1/8� <br /> - 2 - <br /> I <br /> Ilf <br />