My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020 112TH ST SW MAPLEWOOD COURT SITE DEVELOPMENT 2016-01-01 MF Import
>
Address Records
>
112TH ST SW
>
2020
>
MAPLEWOOD COURT SITE DEVELOPMENT
>
2020 112TH ST SW MAPLEWOOD COURT SITE DEVELOPMENT 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2017 8:46:30 AM
Creation date
4/14/2017 8:42:31 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
2020
Tenant Name
MAPLEWOOD COURT SITE DEVELOPMENT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Premise Identi(icatiun Easements - The correcl address of each residenr,e ,erved by Ihe <br />easement access road must be posted upon a permanent sign al the stree} entry to the <br />easement access. In addilion, the correct address must be posted upon or near each residence <br />in such a manner as to be dearly visible and legible from the easement access road. <br />4 Premise Identi(ication • Premises shall be clearly identified by the r,orrecl address at �he sireei <br />entry. D�:il�ings shall be clearly identified so as lo be visible and iegible from the access road. <br />Individual apa�-��ienls and suites, where applicable, shall be c!early and legibly i�enti(ied from <br />llie access road. <br />5. Fire Hydranis - Locations as planned are acceptable. <br />G PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT ACCESS ROADS <br />AND FIRE HYDRANTS SHALL BE IN SE(�VICE PRIOR TO COMMENCEMENT OF <br />CONSTRUCTION. <br />7 Fire flow for this project is 1,000 gpm. If this is nol (easible, an NFPA 13D sprinkler syslem may <br />I�e used in lieu of the required fire (low. Check wi�h Pubiic Works (4251257-7287) for available <br />fire flow <br />El Sinqle Familv or Duplex - Single family or dupiex structures that are required lo have a(ire <br />sprinkler syslem may use a single domestic waler meter (see City of Everelt Public Works <br />Standard Drawing 502C). The size o( the service meter shall be calculated by the civil engineer <br />nr fire sprinkler designer who is soleiy responsibte for these calculations. The Ciry Public Works <br />Department does not review these calculations aud is not the authority having jurisdiction. The <br />fire service side of the syslem must have a state-approved backflow preven(ion device. <br />Construction and demolition of buildings shall be in compliance with the provisions of ihe 2003 <br />In;emational Fire Code, Chapter 14. <br />10 Pennits :�re required from the Fire Uepartment �or removal and installatfon o( underground fuel <br />I;niks <br />KJ iw <br />cc `� f<nh [�iuoks, FnyrPubhc Seivices <br />U��nnis Robersun, Engr/Pub6c Services <br />Lienyam Stephanos, Engr/Public Services <br />Gordon Witcher, EngrlPut�lic Services <br />Glen Mar�insen. F�re <br />
The URL can be used to link to this page
Your browser does not support the video tag.