Laserfiche WebLink
ow ao b ol etruoture (reetrictor cb/bvoasa atruaturels <br />� The City's inspectore request that a detail of the flow <br />control structure be provided on the plans. <br />All orifice sizes and their elevations, as well as the <br />V overflow elevation, should be clearly shown on the detail of <br />the control structure. <br />�v Full details need to be provided for the outlet pipe from <br />� -�r the control manhole. <br />Miscellaneous• <br />City standards require the notes from section 4-2.2(1) of <br />�� th� city�s desiqn and construction standards (notes required <br />on plans) to be included on these plans. <br />A 72 inch manhole (grit removal chamber) isn't required <br />� upstream of a wetpond when a wetvault is provided. <br />Drainage improvements need to be shown for all street <br />�7 improvements. In addition, for 121st, the drainage system <br />��-between the western edge of the site and the stream crossing <br />� needs to be analyzed to ensure that it is adequate to convey <br />collected flows to the creek. <br />