<br /> ❑ ❑ Q Exterior slab Insulation, it not located on the interior, shall be R-10 (Mable 6-2).
<br /> ❑ C [��Exterior E lab Insulatlon, if present, shall approved for below grade use and protected above grade.
<br /> ®Walls, including r Rl joists, shall be insulated withoEt compression to (Table 6-2):
<br /> C'R-15 bait (CHfions 1,11) OR-19 (Option III, W, V, VI,VII)
<br /> �� ❑ Qiaferlor below grade walls shall be insulated without com.aression to (Table 6.2):
<br /> JR-15 (Options I, 11) OR-10 (Options III, V.V, V',VII)
<br /> ❑ ❑ Efaulted ceilings shall be insulated without compression tc R-30(Table 6-2, All options)
<br /> ❑ ❑ Q skylight wall Insulation is installed and equivalent to the iequired wall R-values above.
<br /> ❑ ❑ Vapor retarders shall be Installed toward the warm surface as represented below(502.1.6):
<br /> Select one option for floors, walls, and appropriate ceilingv:
<br /> Floors: 0 Plywood W/exterior glue 0 Poly (, 4 Mil) O Backed balls
<br /> Wails: Poly plastic (;, 4 Mil) 0 Face-stapled, backed batts 0 PVA paint
<br /> Ceilings: Not required where ventilation space averages >12"above insulation.
<br /> Face stapled backed baits O Poly plastic (z 4 mil) O PVA paint
<br /> ❑ C7 s Heating system efficiency and sizing requirements shall be met as represented below:
<br /> ❑ ❑ 8 Heat Pump efficiency shall be met under the following compliance path (S. 503.4):
<br /> O Split system, air source heat pump:HSPF i 6.8, COP > 3.0
<br /> 0 Single package, air source heat pump: HSPF i 6.6, COP > 3.0
<br /> 0 Water source heat pump:COP 2� 3.8
<br /> 0 Ground source heat pump COPi 3.0
<br /> ❑ ❑ 0 Central force-air furnace AFUE rating, as listed in the. GAMA Directory, shall be:
<br /> OZ .78 (Options I, II, IV, VI,VII) 0 a .88 (Option III)) 0>,74 (Option V)
<br /> ❑ ❑ Non-central, combustion heating systems shall have intermitent ignition
<br /> ❑ Fli Maximum heating system output (150%of design heat load) is_J B i U✓hr . (S 503.2.2)
<br /> ❑ ❑ s Hlgh efficiency forced-air furnace (s 56,000 BTU/hr.output)may may exceed 1500,16of DHL
<br /> because: OGAMA listed AFUE is> 78 + 1 per each 5000 BTU/hr output that it exceeds the DHL.
<br /> Insulation phase requirements:CWSEC
<br /> nspectedby: --- Date___
<br /> —
<br /> F Y i7
<br /> ❑ p ,y Envelope Floors shall be insulated without compression, and with support s 24"O.C.to:
<br /> OR19 (Options I, II, III, IV, V) 0 R25(Options VI, VII)
<br /> ❑ ❑ m Non-vaulted,attic callings shall be insulated without compression to: See Table G2
<br /> OR-30 (Options I, II, ol, IV, V,VII) 0 R3B (Option VI)
<br /> Q ❑ Qr Door systems shall meek01.1.40 (All options)
<br /> Door typos are (1)-- (2) (3)--