<br /> C01.1PLIANCC-
<br /> REQUIRED
<br /> ['}� G-1 PIER (fJ!)9, f)ll, plopanJ, 110:11 pufnps) , ZOO') i
<br /> INSP[CT10Nu Ih1PORTANT: Please supply Information In the shaded boxes and check the appropriate
<br /> APPROVED
<br /> circles. Disregard topics that don't describe your building or equipment. DO PIOI place
<br /> checks In the two left columns.
<br /> ❑ ❑ ©Exterior slab Insulation, if not located on the interior, shall be R-10 (Table 6-2).
<br /> ❑ ❑ ©i Exterior slab Insulation, if present, shall approved for below grade use and protected above grade.
<br /> ❑ ❑ QWalls, including rim joists, shall be insulated without compression to (Table 6-2):
<br /> QR-15 ball (Options 1,11) QR-19 (Option 111, ;V,V,VI,VII)
<br /> ❑ ❑ z9 Interlor below grade walls shall be insulated without compression to (Table 6.2):
<br /> QR-15 (Options I, ll) QR-19 (Options III, IV, V.VI,VII)
<br /> ❑ ❑ Qo Vaulted ceilings shall be insulated without compression to R-30(Table 6-2, All options)
<br /> ❑ ❑ Qi Skylight wall Insulation is installed and equivalent to the required wall R-values above.
<br /> ❑ ❑ Q Vapor retarders shall be Installed toward the warm surface as represented below (5027paint
<br /> Select one option for floors, walls, and appropriate ceilings:
<br /> Floors: Q Plywood w/ exterior glue Q Poly (a 4 Mil) Q BacRed balls
<br /> Walls: Poly plastic (i 4 Mil) Q Face-stapled, backed batts Q PVA pai
<br /> Ceilings: Not required where ventilation space oaverages c>124 move insulation.
<br /> Face stapled backed batts Q y plastic (., ) Q
<br /> ❑ ❑ Q Heating system efficiency and sizing requirements shall be met as represented below:
<br /> ❑ Ll < Heat Pump efficiency shall be mot under the following compliance path (S. 503.4).
<br /> Q Split system, air source hoat pump:HSPF i 6.8, COP>3.0
<br /> Q Single package, air source heat pump: 14SP F i 6.6, COP > 3.0
<br /> Q water source heat pump:COP i 3.8
<br /> Q Ground source heat pump COP>- 3.0
<br /> ❑ ❑ 0 Central force-air furnace AFUE rating, as listed in the GAMA Directory, shall be:
<br /> Qi .78 (Options I, Il, IV,VI,VII) 0i .88 (Option III)) 0.24 (Option V)
<br /> ❑ ❑ Qss Non-central, combustion heating systems shall have intermilent ignition
<br /> ❑ ❑ (17)Maximum heating system output (150%of design heat load) is BTU/hr, (S.503.2.2)
<br /> ❑ ❑ a High efficiency forced-air furnace (s 56,000 BTU/11r.output)may may exceed 150%of DHL
<br /> because: QGAMA listed AFUE is:,-, 78 + 1 per each 5000 BTU/hr output that it exceeds the DHL.
<br /> WSEC Insulation phase requirements:
<br /> Inspected by:
<br /> - - — Date_
<br /> 1
<br /> �4,is
<br /> ❑ ❑ Q Envelope Floors shall be insulated without compression, and with supports 24"O.C.to:
<br /> 0R19 (Options I, II, III, IV, V) Q R25(Options VI, VII)
<br /> ❑ ❑ to Non-vaulted, attic ceilings shall be Insulated without( le 6-2
<br /> on to: See Tab
<br /> QR-30 (Options I, I, III, IV, V. VII) Q (option VI)
<br /> ❑ ❑ rr Door systems shall maet:Q U.40 (All options)
<br /> Door types ara (1)__-t2)- --- - (3) -- --- --
<br /> Page 5 of 6