04 <br /> COMPLIANCE 1991 WSEC RESIDEN77AL COMPLIANCE <br /> REQUIRED <br /> INSPECTION <br /> APPROVED IMPORTANT: Please supply Information In the shaded bozos and check the appropriate <br /> circles. Disregard topics that don't describe your building or equipment. DO NOT place <br /> checks In the two left columns. <br /> ❑ ❑ 0 Exterlor slab Insulation, if not located on the interior, shall be R-10(Table 6-1) <br /> ❑ ❑ ©i Exterlor slab Insulation material, it present, shall be approved for below grade use. <br /> ❑ ❑ QQ Walls,Including rim joists,Shall be insulated without compression to (Table 6-1): ` <br /> QR-21 batt (Options I,III,V,VI) R-19 (Option 11, IV, O R-19+R5 foam(Options VII,VIII) <br /> ❑ ❑ ®Interior below grade walls shall be Insulated to (Table 6-1): <br /> Q R-21 (Options I, III,V,VI,VII,VIII) 0 R-19(Options 11, IV) <br /> ❑ ❑ Q'vaulted ceilings shall be insulated without compression to (Table 6-1) R-30 (All options) <br /> ❑ ❑ 01 Skylight wall Insulation is Installed and equivalent to the required wall R-values above. <br /> ❑ ❑ z Vapor retarders shall be Installed toward the warn,surface as represented below(502,1.6): <br /> Select one option for floors, walls,and appropriate ceilings: <br /> Floors; &Plywood W/extertor glue O Poly (z 4 Mil) 0 backed balls <br /> Wails: Poly plastic(4 4 Mil) O Face-stapled, backed baits Q' PVA paint <br /> Cailings:8 Not required whore tentilalion space averages >12"above insulation. <br /> 0 Face stapled backed baits O Poly plastic (r 4 mil) (3 PVA paint <br /> ❑ ❑ a Heating system efficiency and sizing requirements shall be met as represented below: <br /> ❑ ❑ ®Maximum hoating system output(150%of design heal bad) Is KW(S.503.2.2) <br /> ❑ ❑ ©s Heating system requirements will is met with the following system(S.503.4.1.1): <br /> Mfr. Model Max;output_-:—KW <br /> Type ,�t r , .i <br /> ,SEC Insulation phase requirements: <br /> Inspected by: ___ Date <br /> J <br /> ❑ ❑ ©Envelope Floors shall be insulated without compression, and with supports 24"O.C.to R-30 (All <br /> Options,Table 6-1). <br /> ❑ ❑ E7,Non-vaulted,attic ceilings shall be insulated without compression to R-36 (All Options, Table 6.1) <br /> ❑ ❑ 0 Door systems shall meet:nU.40 (Options I, III) a U.20 (Options II, IV, V,VI, VII, VIII,Table 6.1) <br /> Door types are (1)_,I ,• ri , �2)__ _ (3) __ <br /> _ ( t , _ <br /> ❑ ❑ is Exposed foam insulation shall comply as follows (S. 502.1.4.6): <br /> p Protected with metal or plastic flashing or equivalent material that extends below grade. <br /> Pago 5 of 6 <br />