Laserfiche WebLink
i <br /> COMPLIANCE • • • . , ,, <br /> REQUIRED <br /> APPROVEDN IMPORTANT:Disregard topics that don't describe your building or equipment.DO N� <br /> place checks In the two left columns. <br /> F-FINAL PHASE (Conflnued) <br /> I <br /> 0 ❑ Q Alrflow from habitable rooms to whole-house fan ensured by undercut doors or grills (VIAQ, S.302.6.4) <br /> ❑ ❑ Loosefill Insulation OK If(S.502.1.4.5): <br /> ❑maximum ceiling slope <3 ir, 12 <br /> ❑a 30"of clear distance from top of bottom cl,')rd to underside of roof sheathing at the roof ridge. <br /> ❑ ❑ <br /> @6 mll black polyethylene ground cover, lapped 12" at joints and to foundation wall <br /> ❑ ❑ &Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br /> ❑ chimney ❑ Non-IC rated recessed lights: 1/2"to combustables,3"to Insulation. <br /> ❑ ❑ ttic hatch shall be Insulated to required ceiling R-value and Is weatherstripped(S.502.1 3.4) <br /> ❑ ❑ Attic access shall have wood dam or equivalent to retain loose fill insulation in attic(S. 502.1.4.4) <br /> ❑ ❑ it exterior doors (except 20 -ninute doors) shall be weatherstrippod(S.502.4.3). <br /> ❑ ❑ EDService hot & cold water piping shall be insulated to R 3(S.503.11) <br /> ❑ ❑ Service recirculation hot weter piping shalt be Insulated to Table 5.12 levels. <br /> ❑ ❑ D henmostat provided for each HVAC system with range of 55-75' R(heating) (S.503.8.1.1). <br /> ❑ ❑ o Readily accessible,automatic or Manual means provided to restrict or shut-off Heating Input!o each <br /> zone or floor during periods not requiring heat (S. 503.8.3.1). <br /> ❑ ❑ r Controls for backup heat prohibit simillaneous operation of the primary systam (S. 503.2.2(3)). <br /> ❑ ❑ P Mechanical ventilation systems shall have proper timers, and/or switches(S. 302.3). <br /> ❑ ❑ s Mechanical ventilation ducts shall have Insulation i R-4 in unconditioned spaces(VIAQ,S.302.5) <br /> ❑ ❑ ` Mechanical supply ducts in conditioned spaces shall have i R-4 insulation (VIAQ, S.302.5) <br /> ❑ ❑ s uppiy ducts shall have volume dampers, or the equivalent, to balance system(S. 503.6). <br /> ❑ ❑ s Supply and return air ducts shall have sealed e-jct joints in unconditioned spaces (S. 503.10.2). <br /> ❑ U 7 HVAC plenuns,supply,and return air ducts shall have R-8 insulation (Table 5.11, All options) <br /> ❑ ❑ s Electric water heater(s) shall have(S.504.2.1, 504.3, 504.4) : <br /> ❑separate power shutoff ❑ 1987 NAECA Lable on tank <br /> ❑ noncompressible R10 pad (unheated spaces only) v Temperature setting s 120 F. <br /> 1 ❑ ❑ 9 Showers and lavatories shall limit flow to s 3.0 gallons/minute 504.8.1). <br /> ❑ ❑ o Swimming pool(s) (S.504.5) shall have: <br /> ❑readily accessible ON/OFF switch (pump, heater) ❑ Pool cover ❑Piping insulated to S. 503.11 <br /> ❑ ❑ <br /> Fireplace(s) (VIAQ, S.402.3)shall have: <br /> ❑ 6 square Inch combustion air supplyduct w/operable damper, directly connected to the fire box <br /> ❑ Tight filling glass or metal doors;or flue draft induction fan. ❑ Tight fitting flue damper. <br /> ❑ f-3 2 Solid fuel burning appliance(s) (VIAQ,S. 402.2) shall have: <br /> ❑ Tight fitting glass or metal doors <br /> ❑ Outside combustion air sot rce directly connected to the fire box <br /> ❑ Exception: Non-direct, 4"diameter, dampered, combustion air source: allowed only for(1) now stove <br /> installations in existing homes where obstructions preclude direct combustion air,or(2) Central <br /> heating systems located in unheated spaces. <br /> ❑ ❑ J Thren month, etched track, radon monitor, printed Instructions, and an information sheet shall be <br /> supplier'by the builder to each single family dwelling and to each ground floor unit of multi-family dwellings <br /> (VIAQ, S.502.2.1). <br /> SEC Final phase requirements: <br /> 1`nspecfed by Date _ <br /> Page 6 of 8 --- <br />