My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2702 59TH ST SW 2016-01-01 MF Import
>
Address Records
>
59TH ST SW
>
2702
>
2702 59TH ST SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2017 2:36:23 PM
Creation date
4/17/2017 2:36:11 PM
Metadata
Fields
Template:
Address Document
Street Name
59TH ST SW
Street Number
2702
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• I <br /> COMPLIANCE <br /> REQUIRED <br /> INSPECTION IMPORTANT: OQ-N.OI place checks In the two left columns. <br /> APPROVED <br /> ❑ ❑ Exposed foam Insulation shall comply as follows(S. 502.1.4.7): <br /> ❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br /> ❑ Insulation is approved for sub-grade, exterior use and properly Installed. <br /> ❑ ❑ E)Alrflow between fresh air ports and the whole-house fan ensured by undercut doors/grills(VIAQ,S.302.6.4) <br /> ❑ ❑ ®Loosefill Insulation OK If (S.502.1.4.5): <br /> ❑ maximum ceiling slope not>3 in 12 <br /> ❑i 30"of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br /> ❑ ❑ 6 mll black polyethylene ground cover, shall be lapped 12" at Joints and extend to foundation wall <br /> ❑ ❑ a�c Clearances shall meet listed minimums between Insulation and (S.502.1.4.3): <br /> ❑chimney ❑Non-IC rated reces3ed lights:1/2"to combustables,3"to insulation. <br /> ❑ ❑ UAttic hatch shall be Insulated to required ceiling R-value and is wealherstripped (S.502.1.4.4) <br /> ❑ ❑ Attic access shall have wood dam or equivalent to retain loose fill insulation in attic(S. 502.1.4.4) <br /> ❑ ❑ e All exterior doors (except 20 minute do xs) shall be wealherstripped(S. 502.4.3). <br /> ❑ ❑ o Service hot& cold water piping In uncmditioned spaces shall be insulated to R-3(S.503.11) <br /> E] ❑ r Service recirculation hot water piping in unconditioned spaces shall be insulated to Table 5.12 levels. <br /> ❑ ❑ peat pump therindslat shall have prog3mable capability(S. 503.8.3.5) <br /> O ❑ hermostat provided for each HVAC system with range of55-75' F.(healing) (S.503.8.1.1). <br /> eadily accessible,automatic or Mar.ual means provided to restrict or shut-off Healing Input to each <br /> zone or floor during periods not requiring heat (S. 503.8.3.1). <br /> ❑ ❑ s ontrols for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br /> p ❑ Rupply <br /> chanical ventilation system shall have proper timers, and/or switches(VIAO,S.302.3). <br /> ❑ ❑ chanical ventilation ducts shall have R-4 Insulation in unrondirloned spaces (VIAQ, S.302.5) <br /> ❑ ❑ chanical ventilation supply ducts in conditioned spaces shall have R-4 insulation(VIAQ,302.5) <br /> ducts shall have volume dampers, or the equivalent,to balance system(S. 503.6). <br /> ❑ ❑ o upply and return air ducts shall have sealed duct Joints in unconditioned spaces (S. 503.10.2). <br /> C:] ❑ r VAC plenums, supply, and return air ducts shall have R-8 Insulation (Table 5-11,All options) <br /> ❑ ❑ 2 leclrlc water heater(s) shall have (S.504.2.1,504.3, 504.4) <br /> ❑separate power shut-off ❑ 1987 NAECA Labie on tank <br /> ❑noncompressible R10 pad (unheated spaces only) ❑ Temperature setting s 120 F. <br /> ❑ ❑ showers and lavatories shall limit flow to s 3.0 gallons/minute (S.504.8.1). <br /> ❑ ❑ Swimming pools(S.504.5)shall have: <br /> ❑readily accessible ON/OFF switch (pump, healer) ❑Pool cover ❑Piping insulated to S. 503.11 <br /> ❑ ❑ sAll fireplaces (VIAQ,S.402.3)shall have: <br /> ❑ 6 square inch combustion air supplyduct w/ accessible damper directly connected to the fire box <br /> ❑ Tight fitting glass or metal doors. ❑ Tight fitting flue damper <br /> ❑ ❑ 661Solld fuel burning appliances) (VIAQ, S. 402.2) shall have: <br /> ❑Tight fitting glass or metal doors <br /> ❑Outside combustion air source directly connected to the fire box <br /> ❑Exception: Non-direct, 4"diameter, dampered, combustion air source: allowed only for(1) new stove <br /> Installations in existing homes where obstructionsprecludes direct combustion air, or(2) Central <br /> heating systems located in unheated spaces. <br /> ❑ ❑ o)Three month,etched track to the single family famy d elling or first fl or units s ofprinted multi-family dwellings by the generaFcontractor(VIAQ instructions, and Information sheets shall be Sied <br /> 502.2.1), __71 <br /> ' • <br /> WSEC Final phase requirements: <br /> Inspected by: Date <br /> Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.