My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2202 60TH ST SE 2016-01-01 MF Import
>
Address Records
>
60TH ST SE
>
2202
>
2202 60TH ST SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2017 5:09:03 PM
Creation date
4/17/2017 5:08:56 PM
Metadata
Fields
Template:
Address Document
Street Name
60TH ST SE
Street Number
2202
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE <br /> REOUIflED <br /> INSPECTION IMPORTANT: DO NOT place checks In the two left columns. <br /> APPROVED <br /> PHASEI FINAL nued) <br /> ❑ ❑ ®Exposed foam Insulation shall comply as follows (S.502.1.4.7): <br /> ❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br /> ❑ Insulation Is approved for sub-grade, exterior use and properly Installed. <br /> ❑ ❑ ®Airflow between fresh air ports and the whole-house fan ensured by undercut doors/grills(VIAQ,S.302.8.4) <br /> ❑ ❑ ®Looseflll Insulation OK 9 ;S.502.1.4.5): <br /> ❑ maximum ceiling slope not > 3 in 12 <br /> ❑>30'of clear distance from top of bottom chord to underside of roof sheathing at the root ridge. <br /> ❑ ❑ s mil h:dck pol;ethylene ground cover, shall be lapped 12' at Joints and extend to foundation wall <br /> 13 Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br /> r3 chimney ❑Non-IC rated recessed lights: 1/2'to combuslables,3'to insulation. <br /> ❑ ❑ tlu; hatch shall be insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br /> ❑ ❑ e Attic access shall have wood dam or equivalent to retain loose fill Insulation In attic(S. 502.1.4.4) <br /> ❑ ❑ 9 II exterior doors (except 20 minute doors) shall be wealherstripped(S.502.4.3). <br /> ❑ ❑ Service hot a cold water piping in unconditioned spaces shall be Insulated to R-3(S. 503.11) <br /> ❑ ❑ I Service recirculation hot water piping In unconditioned spaces shall be Insulated to Table 5.12 levels. <br /> ❑ ❑ eat pump thermostat shall have progamable capability (S. 503 8.3.5) <br /> El 1:3z helmostat provided for cacti HVAC system with range of 55.75' F.(healing) (S.503.B.1.1). <br /> ❑ ❑ Readily accessible,automatic or Manual means provided to restrict or shut-off Healing input to each <br /> zone or floor during periods not requiring heal (S. 503.8.3.1). <br /> ❑ ❑ s nlrofs for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br /> ❑ ❑ s echanical ventilation system shall have proper timers, and/or Twitches(VIAO,S.302.3). <br /> ❑ ❑ echanical ventilation ducts shall have R-4 Insulation in unc 61.1onad spaces (VIAO, S. 302.5) <br /> ❑ ❑ e echanical ventilation supply ducts in condifimed spaces shall have R-4 insulation (VIAO,302.5) <br /> ❑ ❑ a upply ducts shall have volume dampers, or the equivalent, to balance system(S. 503.6). <br /> ❑ ❑ @DSupply and return air ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br /> ❑ ❑ EDHVAC plenums, supply, and return air ducts shall have R-8 insulation(Table 5-11, All options) <br /> ❑ ❑ z lectrlc water heater(s) shall have (S. 504.2.1, 504.3, 504.4) : <br /> ❑separate power . shut-off ❑ 1907 NAECA Lable on lank <br /> ❑noncompressible R10 pad (unheated spaces only) ❑ Temperature setting-< 120F. <br /> ❑ ❑ @DShowers and lavatories shall limit flow to s 3.0 gallons/minute (S.504.8.1). <br /> ❑ ❑ wlrnming pools(S.504.5) shall have: <br /> ❑readily accessible ON/OFF switch (pump, healer) ❑Pool cover ❑Piping Insulated to S. 503.11 <br /> ❑ ❑ 411 fireplaces (VIAO, S.402.3) shall have: <br /> ❑ 6 square inch combustion air supplyduct w/ accessible damper directly connected to the fire box <br /> p Tight fitting glass or metal doors. ❑ Tight fitting flue damper <br /> ❑ ❑ r Solid fuel burning appllance(s) (VIAQ, S. 402.2) shall have: <br /> ❑Tight fitting glass or metal doors <br /> ❑Outside combustion air source directly connected to the lire box <br /> ❑Exception: Non-direct, 4'diameter, dampered, combustion air source:allowed only for(1) new stove <br /> installations in existing homes where obstructionsprecludes direct combustion air,or(2) Central <br /> floating s/stems located In unhealed spaces. <br /> ❑ ❑ Three month, etched track radon monitor, printed Instructions, and Information sheets shalt be supplied <br /> to the single family dwelling or first floor units of multi-family dwellings by the general contractor(VIAO,S. <br /> 502.2.1), <br /> WSEC Final phase requirements: <br /> Page 6 of 6 — —� <br /> lnspecfed by _Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.