Laserfiche WebLink
April 27, 1987 <br /> Timberplex <br /> Attention: Dick Maultsby <br /> 23607 Hwy 99 <br /> Edmonds, WA 98020 <br /> everett <br /> Subject: 6005 Broadway, permit 417018 <br /> 6007 Broadway, permit 417016 = *• • _+• 9,T9 <br /> t ICPfTT. W9MIY uTO.i <br /> 91101 <br /> Dcar i'Aultsby: <br /> Prior to the issuance of the Certificate of occupancy the following <br /> concerns shall be rectified: <br /> 1. The garage structure is nonconforming as required by Sec 504 <br /> (C) of the Uniform Building Code. A 1-hour separation shall <br /> be provided between 14-1 occupancy (garage) and R-1 occupancy <br /> (apartment house) when the separation is 8 feet or less. <br /> openings in garage walls are prohibited within 8 feet of the <br /> exterior wall of the apartment house structure. <br /> niti;.at;.ng measure: Pre^.id^ a 1-Hour rated sel_aration at the <br /> west wall of the garage. The garage ceiling shall be sheathed <br /> on the underside with 5/8 inch type 'x' Gypsum wall board. <br /> 2. The site plan approved on August 15, 1986 for the issuance of the <br /> building permit is not in agreement with the existing construction. <br /> Mitigating measure: Prepare an as-built site plan showing garage, <br /> decks, walks, steps, finish elevations, complete full plan of <br /> apartment house with all dimensions to property lines and between <br /> structures. Request preliminary review before submitting five <br /> copies to title Buiiuiug Department. <br /> Sincerely, <br /> ALFRED R. THEAL, P.B. <br /> Public Works Director/City Engineer <br /> ��A4' <br /> By Den Edwards -8y <br /> Plans Examiner i O /� <br /> BE/s), <br />