COMPUANcr <br />REQUIRED <br />0 <br />"J <br />n <br />l� <br />LJ <br />INSPECTION IMPORTANT: Supply Information and check appropriate circles In the shaded boxes. <br />APPROVED Disregard topics that don't describe your building or equipment. DO NOT place checks In <br />the two left columns. <br />ING PHASE (Co <br />O ra Prescriptive exhaust ventilation exhaust requirements for each dwelling unit (VIAO, S. 303): <br />Minlmum(.25w.g.) Mfrimodel Fan label(. 1 WG) <br />Kitchen fan 100 CFM <br />Bathroom fan(. ) 50 CFM <br />Bathroom fan(. ) 50 CFM <br />Bathroom fan(. _) 50 CFM <br />Laundry fan 50 CFM <br />50 CFM (1.2 bedrms) <br />15 • ' 80 CFM (3 bedrms) <br />100 CFM (4 bedrms) <br />Whole"house fan: Location _Sone rating (< 1.5 if attic: f.-n closer than 4'to <br />telling) <br />0 Whole house fan is Iistedllabled "for Continuous use". <br />Cl Whole house fan wiring for control routed to central location (de.humidistat only). <br />O E16D Whole house fan also serves as a kitchen or bath spot fan. 0 Yes 0 No <br />(spot fan designated as a whole house fan shall meet+vhcle house fan requirements.) <br />M rz Spot fan Isn't suitable for Wholo house fan and must be soperate 0 Yes 0 No <br />p is Whole house fan shall tun continuously: Kitchen(25CFM), Bath & laundry(20CFM)0 Yes 0 No <br />O r9 Integrated forced-afr furnace ventllatlon(seu lootnofe)(VIAO Code, S. 303.1.2(h)) shall be <br />synchronized with a whole house fan to supply fresh air to the dwelling: 0 Yes 0 No' <br />0 11 yes, a 6" diameter outside air Inlet duct wl motorized damper shall run from the building <br />exterior to the furnace return plenum and limit the ventiltion rate to between .35 - .5 ACH, <br />0 Modifications to the above integrated forced a'r system may require performance testing, in a <br />manner acceptable to the building official, to demonstrate .35 - .5 Air Changes/Hour. <br />'Five bedrooms or larger requires .i designed whole house fan system (Rate is .35 -.5 ACH) <br />©e Mechanical ventilation fan ducts shall be ;�_- 4" and properly sized (VIAQ, Tab'e 3-3). <br />p Q Fresh air shall be provided for each dwelling unit as follows MAID, S. 302.6.1): <br />((((((------��r���ach bedroom: Tested, screened, controllable, through -wall port (2 4 Sq. In.,, to the exterior. <br />0 P,ach recreation room: One wall port as sperified for bedrooms. <br />ther enclosed "habitable" rooms: One wall poll as specified for bedrooms, <br />Overall living area: One wall port as specified for bedrooms. <br />C7 zz)OR Dintegrated forced air furnace which delivers outside makeup airthrough the ducting system <br />WSEC Framing phase requirements: <br />Inspected bV _ — __ _ Dale 1 Page 6 <br />