My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1405 73RD ST SE 2018-01-02 MF Import
>
Address Records
>
73RD ST SE
>
1405
>
1405 73RD ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2021 10:47:20 AM
Creation date
4/17/2017 10:12:04 PM
Metadata
Fields
Template:
Address Document
Street Name
73RD ST SE
Street Number
1405
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE <br />REQUIRED <br />INSPECTION IMPORTANT: AO NOT place Checks In the two left columns. <br />APPROVED <br />PHASEFINAL tiod) <br />❑ ❑ @D Exposed foam Insulation shall comply as follows (S. 502.1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation Is approved for sub -grade, exterior use and properly Installed. <br />❑ ❑ QAIHiow between fresh air ports and the whole -house Ian ensured by undercut dours/grills(VIAQ,S. 302.6.4) <br />❑ ❑ OLoosefill Insulation OK If (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 in 12 <br />❑> 30" of clear distance from top of bottom chord to underside of root sheathing at the roof ridge. <br />❑ ❑ ge 6 mil black polyethylene ground cover, shall be lapped 12" at joints and extend to foundation wall <br />❑ ❑ o Clearances shall meet listed minimums between Insulation and (S.502.1.4.3): <br />❑ chimney ❑ Non -IC rated recessed lights: 1/2" to oombustables, 3" to Insulation. <br />❑ ❑ 0 ttic hatch shall be Insulated to required ceiling R-value and Is weatherstripped (S.502.1.4.4) <br />❑ ❑ FiAtlic access shall have wood dam or equivalent to retain loose fill Insulation in attic(S. 502.1.4.4) <br />II exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />❑ ❑ervice hot & cold water piping In unconditioned spaces shall be Insulated to R-3(S. 503.11) <br />❑ ❑ervice recirculation hot water piping in unconditioned spaces shall be insulated (Table 5-12). <br />❑ ❑ eat pump thermostat shall have progamable capability (S. 503.8.3.5) <br />❑ ❑ lReadily <br />hermoslat provided for each HVAC system with range of 55.75' F.(heating) (S.503.8.1.1). <br />❑ ❑ accessible, automatic or Manual means provided to restrict or shut-off Heating Input to <br />each zone or floor during periods not requiring heat (S. 503.8.3.1). <br />❑ ❑ ntrols for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br />❑ ❑ echanical ventilation system shall have proper timers, and/or switches (VIAQ, S. 302.3). <br />❑ ❑ o echanical ventilation exhaust ducts in unconditioned spaces shall have R-4 Ins. (VIAQ, S. 302.5) <br />❑ ❑ + echanical ventilation supply ducts In rondit oned spaces shall have R-4 ins.(VIAQ, 302.5) <br />❑ ❑ 2 upply ducts shall have volume dampers, or the equivalent, to balance system inq IS. 503.6). <br />❑ ❑ a uppiy and return air ducts shall have sealed duct joints In unconditioned space. (S. 503.10.2). <br />❑ ❑ + VAC p:inums, supply, and return air ducts shall have R-8 insulation (Table 5.11, All options) <br />❑ ❑ a Water hester(s) shall have (S. 504.2.1, 504.3, 504.4): <br />❑ separate power, or gas shut-off ❑ 1987 NAECA Label on tank <br />❑ Elect only: noncompressible R10 pad (unheated spaces, slabs) ❑ Temperature settings 120 F. <br />❑ ❑ @DShowers and lavatories shall limit flow to s 3.0 gallons/minute (S. 504.8.1). <br />❑ ❑ @DSwimmir.g poois(S. 504.5) shall have: <br />❑ readily accessible ON/OFF switch (pump, heater) ❑Pool cover ❑Piping insulated to S. 503.11 <br />❑ ❑ Sa All fireplaces (VIAQ. S. 402.3) shall have: <br />❑ 6 square Inch combustion air suppiyduct w/ accessible damper directly connected to the fire box <br />❑ Tight fitting glass or metal doors. ❑ Tight fitting flue damper <br />❑ ❑ e Solld fuel burning appliance(s) (VIAQ, S. 402.2) shall have: <br />[I Tight fitting glass or metal doors <br />❑Outside combustion air source directly connected to the fire box <br />❑Exception: Non -direct, 4" diameter, dampered, combustion air source: allowed only for (1) new stove <br />Installations in existing homes where obstructions preclude direct combustion air, or (2) Central <br />heating systems located in unheated spaces. <br />❑ ❑@D Three month, etched track radon monitor, printed instructions, and Information ; heets shall be <br />supplied to the single family dwelling or first floor units of multi -family dwellings by the general <br />contractor (VIAQ,S. 502.2.1), <br />WSEC Final phase requirements: Dare_ _ <br />Inspected bt:_ _ _ _ Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.