Laserfiche WebLink
C9MPLIANCE NWEC LC IRISR RESIDENTIAL CO,..PLIANCE CHECKLIST <br />REQUIRED Electrically heated dwellings, s 3 stories, Zone 1, Western Washingtoi <br />INSPECTION <br />APPROVED IMPORTANT: Please supply Information requested In the appropriate <br />shaded boxes below. Disregard boxes that don't describe your building or <br />equipment. DO NOT place checks In the two left columns. <br />PHASE <br />1 En Crawl space Floors will be Insulated without compression, and with adequatesu$Q rt to: <br />❑ R30(Ch #6 Option I) ❑ R19 (Ch #6 Options II, III, IV) 0 Mclh #4, 5, or 7) <br />Non -vaulted, attic ceilings will be Insulated without compresslgQr�to: <br />❑ R-38 (Ch #6, all options) 0dR3h%Ch #4,5, or 7) /44'&_ f SC-jZ`^2 <br />❑ ❑Jnterlor Below grade walls are Insulated without compression to R19Instead of exterior R10. <br />Door systems meet: ❑U.19(Ch#6, (optional, 11, III) ❑U.22(Ch#6, (option IV 0U.2!jjCh#4org <br />Wr [15' Looselill Insulation OK If: <br />1) maximum ceiling slope not> 2 1/2 in 12 <br />2) >30" of clear distance from lop of bottom chord to the underside of roof sheathing at the roof ridge. <br />6 mil polyethylene or other approved ground cover lapped 12" at all joints and to foundation wall <br />tY Cloarances meet listed minimums between Insulation and: <br />1) chimney 2) light fixtures 3) IC rated recessed lights (0' clearance OK) <br />Attic hatch is Insulated to required calling R-value and Is wealherstripped. <br />❑ ❑ All exterior and/or garage to home doors are weathersiripped. <br />❑ ❑ Recirculating service hot water piping is Insulated as checked below(see Uniform Building Code, <br />Sections 1712 &1713, flame spread and smoke density requirements ) <br />1) 1-1/2" Insulation for main lines in attic and crawlspace. <br />2) 1" insulation for branch lines in attic and crawl space. <br />PT <br />M <br />Minimum of one thermostat per HVAC system with proper F range of 55-75' (heating). <br />❑ <br />❑ <br />Readily accessible means to restrict or shut-off heating Input to each zone or floor not <br />controlled by a thermostat. <br />❑ <br />❑ <br />Thermostat setback Is in place and readily accessible.. <br />❑ <br />❑ <br />Backup heating system controls roust prohibit operation when primary heating system is <br />operating. <br />❑ <br />❑ <br />Mechanical ventilation system must have a means for volume reduction and shut-off. <br />❑ <br />❑ <br />Supply ducts must have volume dampers to balance system. <br />❑ <br />❑ <br />Supply and return air ductwork Is required to have sealed duct joints In unconditioned spaces <br />and: ❑i11 insulation (Ch #5 and 6, all options) OR ❑ R_ (Ch #4 Approach) <br />Jfrf <br />® <br />Electric water heater(s) has : <br />1) separate power shut-off 3) ASHRAE 90A-60 label on tank <br />2) noncompressible R10 pad (unheated spaces only) <br />Shower(s) has a means to limit flow to 2.75 gpm or less <br />Fireplaces CP will ❑ will not be Installed Mir_ '50t-c-awrZ Model 34, <br />Woodstoves ❑ will ❑ will not be Installed: Mir. Model <br />All fireplace/stove(s) have: 1)6 square Inch combustion air supply directly conected to the fire box <br />2)Combustion air duct with readily accessible, tight fitting damper. 3) Tight fitting glass or metal doors <br />Masonry flreplace(s) has alight filling flue <br />damper with readily accessible, manual control(s). <br />NWEC Final phase re ulrements: <br />Approved by: <br />Date_ 5 3 <br />WEEK APRIL 60 Page 7 of 7 <br />