My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
615 75TH ST SE 2018-01-02 MF Import
>
Address Records
>
75TH ST SE
>
615
>
615 75TH ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 4:47:30 PM
Creation date
4/18/2017 12:19:54 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
615
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />One-llour Fire -Resistive Occupancy Separation <br />Is required belwecn the boiler or central Ileac• <br />trig plant and the rest of Ihu building. Section <br />BOB. <br />Group 0 <br />49. <br />Group D. Division 1 Occupancies should be of <br />Type 1 or 11 construction unless complying with <br />the Exception in Section 902 (b). <br />50. <br />Group D, Division 2 (3) Occupancies should be <br />of ono -hour fire -resistive construction. Table <br />No. 5 C. <br />51. <br />Light and ventilation should comply with Section <br />905. <br />52. <br />A One flour Fire -Resistive Occupancy Separation <br />Is required belwecn the boiler or central heat• <br />ing plant and the rest of tire building. Section <br />908. <br />53. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should be protected <br />With lhrec•founhs•nour fire resistive assemblies <br />that are fixed, automatic, or self -closing if <br />located below openings in another story or if <br />less than 10 feet frcn• otter doors or windows <br />9n the same building. Section 903. <br />Group E• <br />54. <br />f6otor vehicle service stations should be of non• <br />combustible fire -retardant treated wood or one. <br />hour fireaesistive construction. Section 1102 <br />(b). <br />55. <br />Storage areas in excess of 1000 square feet in <br />Connection with wholesale or retail sales should <br />be separated from the public areas by a one. <br />flour fire -Resistive Occupancy Separation un- <br />less the building is equipped throughoul with <br />Sri automatic tire -extinguishing system. Section <br />1102 (b). <br />56. <br />Light and ventilation should comply with Section <br />1105. <br />57. <br />Exhaust ventilation at or near floor Icvel is re- <br />quired by Section 1105, <br />59. <br />A One f icur rire-Resistive Occupancy Separation <br />is required between a boiler room or central <br />heating plant and The rest of the building. Sec. <br />tion 1108. <br />Group N <br />59. <br />Group N Occupancy more than two stories in <br />height or having more than 3000 square tent <br />1A above the first story should be of ono -hour <br />fire -resistive construction throughout. Section <br />1302 (b). <br />60. <br />The following rooms should have window Areas <br />as specified in Section 1305 (a), one -ball of <br />which is openable. <br />................................................................. _....... <br />.......................................................................... <br />61. <br />hfechanhc l ventilatiog system in bathrooms <br />should provide live air changes per hour di• <br />erectly to the outside. Section 1305 (a). <br />62. <br />%l inflows frorn.......................................... shauld <br />not by ctuli:idercd As funiishing rcquilcd hlfht <br />or verddntion since they do not open to a yard, <br />court, or she,! in accordance with Section <br />63, <br />(:011tl. IWlllldrid Oil later :ides with wall. 611allld <br />be At Tram 10 Ices in Icnl:th. For courts umre <br />Illan live, Mmirs nr ben!hl. the required vndlh <br />should he in; n•a•.ed by one foot and lisp le. <br />I <br />quiied Icniati bl. 2 Wet for caoh additional <br />atury. Section 1306 (W. <br />64. <br />Every sleeping room below the fourth tic,r <br />should have at least one w tsdow or exterior <br />- <br />door Approved for emergency exit or rescue. <br />Section 1304. <br />G5. <br />....................................................... room should <br />have the tninhnum ceiling heictll required in <br />Section 1307 (a). <br />G6. <br />........................................................ room $hould <br />have a minimum superficial floor area of <br />.................... square feel. Section 1307 (b). <br />67. <br />Efficiency dwelling units should comply with <br />Section 1308. <br />G8. <br />A Ono -Hour Firo-Resistivo Occupancy Separation <br />Is inquired between a boiler room or central <br />healing plant and the rest of the builduic. <br />Section 1312. <br />69. <br />Every d.cclling unit and guest room should havo <br />comfort heating facilities as specified In Sec. <br />than 1311. <br />Group J <br />70. <br />Group J Division 1 Occupancies are limited to <br />1000 (3000) square feet In floor area and tree <br />story in height. Section 1502. <br />71. <br />Garages should not open directly into a roam <br />used for sleeping purposes. Section 1504. <br />72. <br />An approved noncombustible material or asphal• <br />lie paving material is tcquired for garage floor <br />surfaces. Section 1504. <br />EXIT REQUIREMENTS <br />73. <br />An occupant load sign is requited in classrooms, <br />essembly areas, etc., having an occupant load <br />of more than SO. Section 3301 (j). See ............ <br />74. <br />Conforming exits are required from the Areas <br />below as specified in Section 3302 (a). <br />............. ..._.,..._............................................... <br />..................... ................................................... <br />75. <br />Exits should have a minimum separation of one. <br />hall file maximum overall diagonal of the build. <br />ing or area served. Section 3302 (c)............... <br />76. <br />NO point In the building should be more than <br />150 (200) feet from an exterior exit, horizontal <br />exit, enclosed stairway, or exit passaccvrry, <br />measured In the direction of travel. Section <br />3302(d)........................................................... <br />77. <br />Exit door should' swing. in the direction of <br />egress. Section 5303 (b), Sae doors ................ <br />..............._..._.................................................... ' <br />78. <br />Double acting doors are not Allowed where sere•- <br />Ing a tributary occupant. load of more than 100. <br />Section 3503 (b), <br />79. <br />Exit doors should be openable from the inside <br />without the use of A key, spcclal knowirdgp• or <br />effort. Section 3303 (c). Note also that Hush <br />bells or surface bolts are prohibited. <br />(10. <br />Exit doors shouted be a minimum sire of 3' x <br />Witte o minimm'll door swing of 90 degrees. <br />Sectholl 3303(d)............................................... <br />61. <br />The net dnnrnzion (clear width) at donlv:avc <br />Sllnllld Ile u:ell III rlelrrrlrillllll! rill 1vr1I'P, <br />Ierpllred by Utmition 3302 (11), :.,.Cli,lll 3'310 <br />(d). In rmrusera Linn rel done tlucknc.srs• pare- <br />hardware, dnnr swine, plc., the required cot <br />Widths hara not hren IIIr11MIlVd. :ice darer <br />
The URL can be used to link to this page
Your browser does not support the video tag.