My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
615 75TH ST SE 2018-01-02 MF Import
>
Address Records
>
75TH ST SE
>
615
>
615 75TH ST SE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 4:47:30 PM
Creation date
4/18/2017 12:19:54 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
615
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C2. <br />A floor or landing riot more than 1 inch below <br />the threshold is required on each side of an <br />exit door. Section 3e03 (h). <br />83. <br />Doors should not pro;ecl more than 7 inches in. <br />to the required corridor width when rutty <br />opened or more than one hall inin the required <br />corridor width when in any position. Section <br />3304(d)........................................................... <br />K <br />IRevolving (sliding) (overhead) doors are not per. <br />milled as exit doors. Section 3303 (1). <br />85. <br />Exit doors should provide immediate access to <br />an approved means of egress. Section 3303 <br />(C)• Exiling through another room does not <br />comply. <br />EG. <br />should have a minimum width of 44 <br />ICorridors <br />inches. Section 3304. (b). <br />87. <br />serving nonembulatory persons should <br />ICorridors <br />have an 8-foot minimum width. Section 3318 <br />(c). <br />CS. <br />end of corridors and exit balconies are <br />IDead <br />limited to 20 fact. Section 3304 (f). <br />E9. <br />)Salts and callings of corridors should to of one. <br />hour fire•resistive construction. Section 3304 <br />(C)• An architectural section through the corri• <br />dor is necessary to determine how this is <br />accomplished. <br />90. <br />' exit balconies cannot project into an <br />area %-,Here protected openings are required <br />- <br />lExtetior <br />due to location on property. Section 3304 (1). <br />......................................................................... <br />91. <br />openings Into corridors should be pro• <br />Ilnterfor <br />leered as specified in Section 3304 (h). <br />92. <br />............................. _........... shouirl have <br />a minimum width of .....L.s...:....... inches. Trim <br />1Stairway <br />end handrails should not project more than <br />31/a Inches into the required width. Section <br />3305 (b). <br />93. <br />on stairways should not exceed 7i,? <br />ipisers <br />Inches and runs should riot be less than 10 <br />inches. Section 3305 (c). <br />94. <br />Landings on stairways Should have a dimension <br />In the direction of travel equal to the width of <br />the stairway but need not exceed 4 feet. Sec. <br />tion 3305 (f). <br />95. <br />Landings should not be reduced in width more <br />than 31/•, inches by a door when fully o;cn. <br />Section 3305 (f). <br />96. <br />portion of stninvoys should have an <br />I8asemenl <br />approved barrier where continuous to uprer <br />floors in an exit enclosure. Section 3305 (C). <br />97. 1 <br />Vertical distances between stairway landinLt are <br />• <br />r I <br />limited to 12 feel. Section 3305 (II). <br />93. t <br />Nondrails Should be placed not less than 30 <br />' <br />nor more than 34 inches above the <br />Ifollies <br />tread. Section 3305 (1). Two handrails are re• <br />quired where stairways exceed 44 inches in <br />width. <br />09. IGuaidrails <br />for stairs• balconies, and landings <br />should conform with Section 1714. Note that <br />nlaximunl clearancr, between inlelmedlale rails <br />I1 <br />is 9 Inches. <br />103. 10pcnings <br />in exterior walls within 10 feet of <br />exlclior stairways should he protected will, <br />Self closing three felltths4lour fire resistive as. <br />selllhlles, Svchon 3,iO5 (k). <br />101. <br />'Enclosed <br />usable spare under interior stairways <br />ahmild Pe proterted on the enrlosed suie os <br />rrqun,d lot onehnur fire n•sm4no cunslnrc- <br />ltmll. t,rchnrl 330, (1). <br />102✓ <br />Nor¢mdmslflJn exterior stairs are fa uucA. <br />■ <br />103. <br />Exterior stairs should not project into an area <br />(yards or courts) where wail upenulgs must be <br />protected. Section 3305 (m). <br />104. <br />Ono stave.,ay should extend to the roof. SCellon <br />3305 (n). It must be in a smakeprool encldsurd <br />In buildings over 75 feel In height. Section <br />3309 (It). <br />105. <br />Six-foot 6-inch rninimurn headroom clearance for <br />stairways should he indicated on plans. Section <br />3305 (o). Note that this is from a plane fall - <br />gent to the stairway tread nesings. <br />JOG. <br />Ramp slopes should nv, exceed one feet in <br />................................. feel. Section 330G (c) M. <br />107. <br />Surface of ramps should be roughened or of <br />nonslip material. Section 3306 (f). <br />108. <br />Stairways should be enclosed as specified in <br />Section 3303. 1' <br />(a) One (bvo)•hour fire -resistive walls are re- <br />quired. <br />(b) Only exit doors are allowed to open Into exit <br />enclosures. <br />(e) Doors should be labeled one (one•and onc• <br />half) -hour fire assemblies. <br />(d) Exit enclosures should include a corridor on <br />the ground floor extending to the exterior. <br />rire•resistive construction Should be as re- <br />quired for the exit enclosure, Including pa - <br />Jetted openings. Only exit doors are per. <br />milted to open into the corridor. <br />(a) An approved barrier is required at the <br />ground floor to prevent peop,e from acci- <br />dentally continuing to the Imser level. <br />(f) Usable space is not allowed under the <br />stairs. <br />109. <br />One exit from the building shotdd be a smovc^ <br />proof enclosure complying with Section 3300. <br />110. <br />Openings into exit courts less than 10 fee: wide <br />should be protected with labeled 45•mtnute I-rc <br />assemblies. Section 3310 (d). Xso see "aril <br />court" definition 1n Section 3301 (c). Openings <br />more than 10 feet above file court floor are <br />exempt. <br />' <br />I11. <br />No openings other than required exits are per- <br />mitted In exit passageways. The p3ssagcvays <br />should be of ........................ •hour fire -resistive <br />construction. Section 3311 (a). <br />112. <br />Exit illumination and signs should be provided in <br />conformance with Section 3312. <br />113: <br />Aisle (cross aisle) In auditorium should have . <br />minimum widths of ............................... Section <br />3313 (b). Section 3313 (a). _ <br />114. <br />Oriole harde•are Is required on exit doors serving <br />Group D occupancies h3vin8 an occupant Icad <br />of more than 103. Section 3316 (a). In lieu <br />of this, doors strip have no locks or ILIcheS. <br />115. <br />..1nin and side exits in Conformance with Sec. _ <br />lion 3315 are required for U-7. (1) Occupancies. <br />Section 3316 (a). <br />116. <br />Corridors of Group C Occupancies 5hatdd havo a <br />width required fly Section 33W plus 2 feet• but <br />not less than G hoot. Section 3317 (e). <br />117. <br />Each floor ibm•e or below the Clound poor level <br />Ed Group C occupancies should have no Wes <br />than two exit stairs. Section 3317 (c). <br />111). <br />Lxd slants serving an mraglanl load of mmr,: <br />than !u0 in a Group C Ocrupanty should how• <br />a utinimum clear wuRli of b feet. Section 3317 <br />(0. <br />119. Lvely tooth will an occupant load axcerdugt <br />300 Should hait mu of fit. exit,. Into a t.t ,,ualo <br />
The URL can be used to link to this page
Your browser does not support the video tag.