My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1525 75TH ST SW TCI 2018-01-02 MF Import
>
Address Records
>
75TH ST SW
>
1525
>
TCI
>
1525 75TH ST SW TCI 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 3:20:29 PM
Creation date
4/18/2017 1:02:25 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1525
Tenant Name
TCI
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. The following exit and exit -access doors which serve in the means of egress system for <br />the A-3 Occupancies should be shown to have panic hardware, unless no lock or latch <br />will be used: 128.2, 134, 136, 137, 138, 154.1, 154.2, 157, 157.1, 101, 101.1, 163 & <br />163.1. Sections 1007.2.5 & 1003.3.1.1 <br />5. It should be verified that Door 163.2 has a 20-minute rating. Section 1004.3.4.3.2.1 <br />6. Illuminated exit signs should be shown at the doors within the A-3 Occupancies and on <br />each side of doors 134 & 163. Section 1003.2.8.2 <br />Accessibility <br />1. The bottom edge of vision panels within doors should be shown no higher than 43" <br />above the finished floor. Section 1106.10.7 <br />2. Toilet room 178 should be shown to be accessible, even though other accessible <br />facilities exist on that floor. Section 1105.2.2 <br />3. The hot water and drainpipes exposed under lavatories should be insulated or <br />otherwise covered. Section 1106.11.7.4 <br />Energy <br />1. The plans should indicate which areas are to comply as heated or semi -heated spaces <br />for envelope requirements. Please note those requirements per Section 1310.2 & 'fable <br />13-I. <br />Prepare a rcponse ietter showing where each item in this correction letter is addressed <br />on the plan set. <br />Upon resubmital of the drawings, your application will be given priority and plan review <br />will commence. <br />All required submittals shall be of sufficient detail and contain sufficient information to <br />ensure that th, proposed structure will be constructed in compliance with all adopted <br />codes. <br />Sincerely, <br />To I c <br />Associate Engineer <br />TL:j1:661945 <br />
The URL can be used to link to this page
Your browser does not support the video tag.