Laserfiche WebLink
Tony Lee <br />0410a199 <br />Page 2 of 2 <br />Me following exitaid exit -access doors w* h serve 0 Memews of egress system for Ne A-3 Occupwcic s should be shown to have panic <br />hardhare, nnlessnolock or latch wil'h, 1282, 134 136 137 138 154 1, 1542, 157, 1571. IOI 101.1, 163, & 1631 SecOons <br />1007 2 5 d 1003 3 1 1 <br />We agree and will comply. Note that the hardware for doors 101, 128.2, 154.1, 157, & 163.1 are <br />exterior doors. ThL3e doors and their hardware will be scheduled In the Core & Shell Package to be <br />submitted for permit review on 4/9/99, See Door Scher:ule on Sheet A11.1. <br />gshouldbevenfiedMat Doty 1632hasa20-minufera6ng SecAen190434321 <br />There was a door on the drawings which was mis-numbered. The door from Room 16B to Room <br />128 should have been numbered 168.1. That door is now scheduled to be 50-minute rated (See <br />Item 2. move). The exterior door at the south end of Room 163 should be numbered 163.2. That <br />door is an existing door to remain and it is not requirFd to have a fire rating. See Sheet A4.1 and <br />Door Schedule on Sheet A11.1 <br />6 llluminaled exit signs should be shown at Me doors within Ale A-3 Occupancies and en each sido of doors 134 & 163 Section 1003 2 8 2 <br />We agree and will comply, except that, due to the modifications described In Item 2. above, Door <br />134 only needs an exit sign on the side to Room 134 and Door 163 only needs a sign on the side to <br />Room 160. See Sheet A9.1. <br />✓ Accessibili <br />1. 7ne bohom edge of vision panels wihin doors should b, shown no higher Nan 43"above Me finished floor Section 1106.10.7 <br />We agree and will comply. See Sheet A 11.1. <br />2. Toilet Roam 118 should be shown lobe accessible, even Noagh other accessible racilites exist an Mal Aonr Section 11052.2 <br />We agree and will comply. See Sheet A7.1. <br />3 The hot water drain pipes exposed under lavalevies should be insulated or oMa*se covered Section 1106 117 4 <br />We agree and will comply. See Sheet A6.1. <br />Enerav <br />- x 1, the plans should indicate which areas are to comply as heated or semi -heated spaces for envelope requirement. Please note Nose <br />requirements per Section 13102& 7aYe 13-1 <br />On Sheet GO.1, we have added an Energy Envelope description. You will note that there are no <br />areas of semi -heated space. <br />We hope that you will find this information to be satisfactory to resolve your concerns regarding this plan <br />review. If you have any questions or require any further Information, please contact us. <br />Sincerely, _ <br />Haynes Lund, AIA <br />Project Architect <br />Sabey Corporation Architecture Group <br />cc: rue. <br />E %&2KWRETTITCAEVRT0aAP.DOC <br />