Laserfiche WebLink
COMPLIANCE <br />REQUIRED V <br />Cl <br />INSPECTION IMPORTANT: Supply Information and check appropriate cllcles In the shaded boxes. <br />APPnovEo Disregard topics that don't describe your building or equipment. OO.NC_T place checks in <br />I--- the two left columns. <br />ILA <br />III <br />I=_1 <br />u <br />O <br />L7 <br />AM14G PHASE (Continued) <br />Exhaust ven',Ilation shall be provided for each dwelling unit as follows (VIAQ S. 303): <br />Location <br />Minimum at .25 w.g. Mfr./model <br />Fan label CFM;J W.G.) <br />Kitchen Ian <br />100 CFM <br />Bathroom fan(:'. A _) <br />50 CFM <br />Bathroom fan(: - <br />) <br />50 CFM <br />L ithroom fan(_ <br />) <br />50 CFM <br />L aundry Ian <br />50 CFM <br />Wrhole house fan' <br />(choose one) <br />Q 50 CFM (1-2 bedrms) <br />® 60 CFM (3 bedrms) <br />Q 100 CFM (4 bedrms) <br />— <br />— <br />Whole house fan: Location _Sone raring4'•- (s 1.5 it attic fan closer than 4'to <br />cei"ng) <br />(� Whole house fan is listedlabled "for Continuous use'. <br />�) Whole house lan wiring for control routed to central location (delrumidrslat only). <br />D`Wholo house tan also serves as a kitchen or bath spot fan. # Yes Q No <br />If a spot fan Is designated as a who!e house fan, the capacity shall be the larger CFM requirement.. <br />J Whole house fan shall run continuously: Kitchen (25CFM); Bath & laund.'(20CFM) QYes @ No <br />D Integrated forced -air furnaco ventilation (IAO Code, S. 303.1.2(b)) shall be synchronized with a <br />whole house tan to qupply fresh air tulhe dwelling: ® Yes Q No <br />II yes, a 6' outsido air inlet duct w/ motorized damper shall run from the building exterior to to <br />the furnace return plonum and limit the voMillion rate to between .35 - .50 Air Chang aaff-lour. <br />Q Modifications to the above Integrated forood air system may require podormance tesillo, Ina <br />manner acceptable to the Building Official, to demonstrate .35 -.5 air changes per hour. <br />0 I D Mechanical ventllatlor fan ducts shall be a 4" and property sized (VIAQ,Table 3-3) <br />p z' Fresh air shall be prr video for each dwelling unit as follows (VIAO, S. 302.6.1): <br />Each bedroorn: Tested, screened, controllable, through -wall port (i 4 Sq. in) to the exterior. <br />Q Each Recre.allon room: One wall port as specified for bedrooms. <br />Other enclosed "habitable" rooms; One wall port as specified for bedrooms. <br />Overall living area: One wall port as specified for bedrooms. <br />O eDOR #Central forced air furnace which delivers outside makeup air through the ducting syslem. <br />E-:] Q Recessed lighting fixtures (S. 502.4.4) shall comply wl one or more of the following: <br />® 10 rated, with no slots or holes in cans, caulked or sealed between can and ceiling <br />Q IC rated with table certifying an ASTM E263 tested aideakage s 2.0 CFM <br />Q Any UL listed fixture enclosed by a 1l2` gypboard box or other manufactured box <br />w/ 1/2' clearance to combustables, and X clearance V) insulation. <br />WSEC Framing phase requirements: <br />Inspected by _— _-- <br />Page 4 of 6 — <br />Date __ <br />