Laserfiche WebLink
c� <br /> Rosc Homes- Plan Check No. CO 105-026 <br /> Page 4. <br /> 21. Show all plate heights on elevation views. c <br /> This has been added to Sheet 1. <br /> 12. Show base (average) clevaton from height calculations on elevation. <br /> This has been marked on the site plan. <br /> 23. Thu front mill on the.second floor is shown as 2x4 eo,cetruction. R-19 insulation <br /> is required in exterior walls. <br /> All walls, except for the garage are 2X6 construction. Insulation is shown on <br /> Sheet 2. <br /> 24. 2X10 rafters do not provide su/rcient depth jnr R-38 insulation (as plan s/ecifre.�) <br /> and a one-inch airspace. <br /> Rafters have b,-en changed to 2X12, Sheet 4. <br /> 25. Specify rafter framing size and spacing at porch. <br /> This has been added to Sheet 4. <br /> 26, provide detail ofattic ventilation at enclosed soffits. Elcvahons do not show <br /> enclosed snffats. Ifsojjtts are not enclosed provide detail if rafter overhang. <br /> Overhanging rafters are shown on the building cross-sections, Sheets 4 and 5. <br /> 27. ,Show 8" max step dawn!o floor or first step or landing. Added to page 2landings <br /> This has been added to Sheet 2, landing notes. <br /> 28. flandrails should he shotirn on theJloor plans. <br /> These have been added to Sheet 2, referencing typical handrail detail. <br /> 29. Plan vieuw shous• no window nest to the front door. <br /> Safety-glazed window added to Sheet 2. <br /> JARNOT ENGINEERING INC. <br />