ENGINEERING / PUBLIC SERVICES DEPARTMENT <br /> June 9,2006 <br /> Tony Shapiro <br /> A.D. Shapiro Architects,PS <br /> 624 Edmonds Way <br /> Edmonds, WA 98020 <br /> Project: 321 Bounce <br /> Job Address: 111 180th Street <br /> Plan Review No: B0604-065 <br /> Dear Mr. Shapiro: <br /> In response to your application for construction permit,the plans ha%e been examined and you are advised that a <br /> permit cannot be issued until the following issues arc resolved. These comments address building issues only. <br /> Revisions or additions may be required by other departments(such as Utilities,Planning or Fire). Code <br /> references cited include the 2003 International Building Code(IBC),the 2003 International Mechanical Code <br /> (IMC),the Washington State Energy Code, 2003 edition,and the Accessible and Usable Buildings and Facilities <br /> ICC/ANSI A117.1-2003 (ANSI),as revised by the State of Washington and as adopted by the City of Everett. <br /> In order for the processing your application to continue,It will be necessary to provide the Building <br /> Division with two sets of drawings reflecting the corrections requested. <br /> Construction <br /> 1. After reviewing the plans and the 3-2-1 Bounce website,we agree that the entire facility is an A-3 <br /> occupancy. <br /> 2. The building as originally designed had unlimited area per the provisions of the UBC. Current IBC <br /> provisions would preclude A-3 occupancies in unlimited area buildings,per IBC Section 507.2. The <br /> allowable arca justification for the building should be provided per the provisions of Section 506.1. <br /> 3. For occupancy calculations,we would calculate the occupant load as follows: <br /> If offices are exclusively used for employed staff,the occupant load of those rooms can be calculated at <br /> 100 square feet per person. The second floor should have an occupant load calculated at 15 square feet <br /> per person,and the first floor high bay areas should have an occupant load calculated at 50 square feet <br /> per person. <br /> Please review and indicate one occupancy calculation on the drawings, for a single total occupant count. <br /> 4. Two exit discharge doors arc currently shown on the documents. With an occupant load over 500,three <br /> exits should be shown on the plan per IBC Table 10 18.1,separated by one third the maximum diagonal <br /> distance of the space,per the exception to Section 1014.2.2. <br /> 5. All doors used for egress and new doors should be labeled on the plans to indicate the type of door <br /> provided. All doors should provide 32 inch clearance between the open face of the door and the stop, <br /> per IBC 1008.1.1. Panic hardware should be provided on all egress doors,per IBC 1008.1.9. <br /> CITY OF EVERETT• 3200 Cedar Street• Everett,WA 98201 • (425)257-8800• Fax(425)257-8856 �r <br /> aw11k7%ftf,0"-%5iim801hSn <br />