Laserfiche WebLink
PC 48522 <br /> june 23, 1995 <br /> Page 3 <br /> 16. Handrails must have their ends returned or terminate in newel posts or safety <br /> terminals. Section 3306(1). <br /> 17. At last one handrail shall extend at least 12 inches beyond the top riser and 23 <br /> inches beyond the bottom riser. Section(i). <br /> 18. Guardrails for stairs, balconies and landings shall conform with Section <br /> 1712(a). Note that maximum clearance between intermediate rails is less than 4 <br /> inches and guardrail height should be 42 inches. (Guardrails at the sides of <br /> open stairways may have a height as permitted for handrails.) Section 1712(a). <br /> 19. Provide exit signs in conformance with Section 3314. <br /> 20. Please provide information/details of draft curtains heat/smoke vents, <br /> emergency access doors, and hose requirements per article 81 Uniform Fire <br /> Code. <br /> L/21. Please indicate a north arrow on the site plans. <br /> V 22. Accessible doors shall have maneuvering clearances per Section 31060)3. This <br /> item applies to door number 28. <br /> 23. Provide signage per Section 3106(p) to accessible parking spaces, entrances <br /> (when not all entrances are accessible), toilet and bathing facilities (when not all <br /> are accessible) and at every major junction along or leading to an exterior <br /> accessible route of travel. Section 3103(b)4. <br /> 24. All exterior exits which are located adjacent to accessible areas and within 6 <br /> inches of grade shall be accessible. Section 3104(c). <br /> 25. In multi-story buildings or portions thereof required to be accessible by Section <br /> 3103, at least one accessible elevator shall serve each level, including <br /> mezzanines. Section 3105(c). <br /> v' 26. Controls, operating mechanisms and hardware shall be accessible in accordance <br /> with Section 3106(c). Section 3105(d)8. <br />