My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1125 80TH ST SW 2016-01-01 MF Import
>
Address Records
>
80TH ST SW
>
1125
>
1125 80TH ST SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2017 9:09:17 PM
Creation date
4/18/2017 9:08:47 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1125
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
229
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PCa48522 <br /> June 23, 1995 <br /> Page 2 <br /> 7. Overflow drains having the same size as roof drains and on independent drain <br /> lines are required. In lieu of this, overflow scuppers three times the size of roof <br /> drains can be installed in parapet walls. The overflow drain system is required <br /> to have inlets located 2 inches above the low point of the roof. Section 3207(c). <br /> ,/8. Glass and glazing shall comply with Chapter 54. Type and thickness of glass <br /> must be specified. <br /> 9. Exit doors must swing in the direction of exit travel. Section 3304(b). This <br /> /10. <br /> item applies to door number 30. <br /> v 10. A floor or landing nor more than one inch ('fi") below the threshold is required <br /> t�r1, on each side of an exit door. Section 3304(i). This item applies to door <br /> number 16. <br /> �/I 1. Exterior stairs and exit balconies cannot project into areas where openings are <br /> not permitted or are required to be protected. Section 3305(i) and 3306(m). <br /> 'Phis item applies to exit door number 16. <br /> 12. Risers on stairways shall be not less than 4 inches nor exceed 7 inches, and runs <br /> (treads) shall be not less than I I inches. Section 3306(c). Please provide stair <br /> sections for exterior and interior stairs. <br /> 13. The top of handrails are to be placed not less than 34 inches nor more than 38 <br /> inches above the nosing of treads. Section 3306(1). <br /> 14. Handrails projecting from a wall must have a space of not less than 11/2 inches <br /> between the wall and the handrail. Section 3306(1). <br /> 15. The handgrip portion of handrails shall be not less than 11/2 inches nor more <br /> than 2 inches in cross sectional dimension or the shape should provide an <br /> equivalent gripping surface. The acceptability of equivalent shapes will be <br /> determined by the building official. The handgrip portion shall have a smooth <br /> surface with no sharp corners. Section 3306(i). <br />
The URL can be used to link to this page
Your browser does not support the video tag.