COMPUANCE
<br />REQUIRED
<br />Will
<br />I
<br />NSPECTrON IMPORTANT: Please supply Information In the shadrd boxes and check the appropriate
<br />APPROVED
<br />circles. Disregard topics that don't describe your building or equipment. pace
<br />checks In the two left columns.
<br />7ii4S�A,77ON PHASE
<br />❑ © Exterior slab Insulation, if not located on the inferior, shall be R-10 (Table 6-2).
<br />❑ Exterior slab Insulation, if present, shall approved for below grade use and protected above grade.
<br />❑ ©Walls, including rim joists, shall be insulated without compression to (Table 6.2): -
<br />OR-15 ban (Options 1,19 R-19 (Option ill, iV, V, Vl, VII)
<br />❑ ®Inlerfor below grade walls shall be insulated without compression to (fable 6.2):
<br />OR•15 (Options I,11) 6A-19 (Options III, IV, V. VI, VII)
<br />❑ oo Vaulted ceilings shall be insulated without compression to R-30 (Table 6-2, All options)
<br />❑ i>t Skylight wall Insulation Is installed and equivalent to the required wall R-values above
<br />W
<br />IN
<br />D Vapor retarders shall be Installed toward the warm surface as represented below (502.1.6):
<br />Select one option for floors, walls, and appropriate ceilings:
<br />Floors: Plywood WI exterior glue p Poly (a 4 Mil) p Backed batts
<br />Walls: Poty plastic (z 4 Miq Q Face -stapled, backed bans PVA;paint
<br />Ceilings: Not required where ventilation space averages >12" above insulation.
<br />Face stapled backed batts 0Poly plastic (a,4 m1) O PVA paint
<br />Heating system efficiency and sizing requirements shall be met as represented below:
<br />Heat Pump efficiency shall be met under the following compliance path{S 503.4):
<br />0 Split system, airsource heat pump: HSPF Z 6.8, COP > 3 r , -" -
<br />p Single package, air source heat purr,): HSPF z 6.6, COP , 3.0
<br />Q water source heat pump: GOP > , .E
<br />Ground source heat pump COP> 3.0
<br />Ce�ntrCal force -air furnace AFUE rating, as listed in the GAMA Directory, shall be:
<br />( z _78 (Options 1,11, IV, VI, VII) Q > .s8 tOption ill)) , Qi 74 (OPWn V)
<br />e Non -central; combustion heating systems shall have intermhent ignil n BTUmL (S. 50322) -
<br />r7 Maximum heating system output (150 /o of design heat load) is "'7so°42
<br />ra High efticlency toned air lumace (s 56,000 BTU/f1r. ouiput)maymay exceed 150%ot DHL '
<br />because: QGAMA listed AFUE is i 78 + 1 per each 5000 BTUlhroutput that it exceeds the DHL,.
<br />WSEC insulation phase requirements:
<br />Date__—
<br />inspected by
<br />,
<br />FWAL PHASE
<br />Envelope F rs shall be Insulated without compression, and with support-<24" O C to:
<br />t9 (Opttons 1,11,111; N, V) 0R25 (Optlotis Vi; Viq
<br />Non•vattic ceilings shalt be Insulated without compression for See Table 6.2
<br />t��(Options 1,11,111, IV, V, VIi) p R38 (Option VI)
<br />]Door systems shall meet:QU.40 options) +r �
<br />Doortypes are (1) d P ^t i S 12) F+-usw WOO �)
<br />Page 5 of 6