Laserfiche WebLink
COMPUANCE <br />REOUIRED Ee <br />INSPECTION IMPOI ,TANT: nn NO.I place checks In the two left columns. <br />APPROVED i <br />I FINAL PHASE .s <br />❑ ❑ Q Exposed foam Insulation shall comply as follows (S. 502.1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation is approved for sub -grade, exteror use and property Installed. <br />❑ ❑ a@)Alrflow between fresh air pods and the whole -house fan ensured by undercut doors/gdlls(VIAO,S. 302.6.4) <br />❑ ❑ ®Looseflll Insulation OK it (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 In 12 <br />❑> 30" of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />❑ ❑ mil black polyethylene ground cover, shall be lapped 12" at Joints and extend to foundation wall <br />❑ ❑ 6 Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br />❑ chimney ❑Non -IC rated recessed lights:1/20 to combustables, 3' to insulation. <br />❑ ❑ Attie hatch shall be Insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br />❑ ❑ Attic access shall have wood dam or equivalent to retain loose fill insulation In attic(S. 502.1.4.4) <br />❑ ❑ II exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />❑ ❑ Service hot & cold water piping in unconditioned spaces shall be Insulated to R-3(S. 503.11) <br />❑ ❑ f Service recirculation hot water piping In unconditioned spaces shall be Insulated to Table 5-12 levels. <br />❑ ❑ ®z Heat pump thermostat shall have progamabie capability (S. 503.8.3.5) <br />❑ ❑ GztThernostat provided for each HVAC system with range o155-75' F.(healing, ;S.503.8.1.1). <br />❑ ❑Readily accessible, automatic or Manual means provided to restrict or shut-off Heating input to each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). <br />❑ ❑ ntrois for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br />❑ ❑ hanlcal ventilation system shall have proper timers, and/or switches (VIAO. S. 302.3). <br />❑ ❑ hanical ventilation ducts shall have R-4 Insulation in uncondirloned spaces (VIAO. S. 302.5) <br />❑ ❑ hanlcal ventilation supply ducts In nnndltloned spaces shall have R-4 Insulation (VIAO, 302.5) <br />❑ ❑ upply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />❑ ❑ upply and return air ducts shall havesealed duct Joints in unconditioned spaces (S. 503.10.2). <br />❑ ❑ VAC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11, Ali options) <br />❑ ❑ z lectrlc water heater(s) shall have (S. 504.2.1. 504.3. 504.4) 0 1987 NAECA Lable on tank <br />❑ separate power . shut -on <br />❑ noncompressible R10 pad (unheated spaces only) ❑ Temperature setting s 120 F. <br />❑ ❑ ®Showers and lavatories shall limit flow to s 3.0 gallons/minute (S. 504.8.1). <br />❑ 0 �}i Swimming pools(S. 504.5) shall have: <br />❑ readily accessible OWOFF switch (pump, heater) ❑Pool cover ❑Piping Insulated to S. 503.11 <br />❑ ❑ All fireplaces (VIAO, S. 402.3) shall have: <br />❑ 6 square inch combustion air supplyduct w/ accessible damper directly connected to the fire box <br />0lld fuel buTight rning appliance(s) glass or laence(s) (VIAO, S. 40tal doors. ❑2. )Ishallfining <br />havve: damper <br />❑Tight fining glass or metal doors <br />❑Outside combustion air source directly connected to the fire box <br />air sou <br />In❑stallatiotns in existing homes i here obstrup tionsprem udesodirret combust on aiir only(2) Cent for <br />alw stove <br />heating systems located In unheated spaces. <br />❑ ❑ r Three month, etched tack radon monitor, printed instructions, and Information sheets shall be supplied <br />to the single family dwelling or first floor units of multi -family dwellings by the general contractor (VIAO,S. <br />502.2.1), <br />W EC Flne please requirements: Data — <br />Inspected by: — <br />Page 6 of 6 <br />