Laserfiche WebLink
co <br />RE <br />H <br />MPl1ANCEIffI <br />MPLIANCICHECKLIST <br />OUIREO <br />INSPEC IMPORTANT: Please supply Information In the shaded boxes and check the appropriate <br />arrnovED e0 pp Y <br />circles. Disregard topics that don't describe your building or equipment. DO -NOT place <br />�checks In the two left columns. <br />■!NSt� ►IllNIJiAE <br />❑ ©Exterior stab Insulation, if not locatod on tho Interior, sliall bo R-10 (Table 6-1) <br />❑ ©i Exterior slab Insulation material, if present, shall be approved for below grade use. <br />❑ E'je Wails, Including rim )olds, Shall be Insulated without compression to (Table 8-1); <br />OR-21 belt (Options I,III,V,VI) 0 R-19 (Option II, IV) o R-194 R5 1011111 (Options VII,VIII) <br />❑ ®Interlor below grade walls shall be Insulated to (Table 6-1): <br />0 R-21 (Options I, III,V,VI,VII,VIII) 0 R-19 (Options II, IV) <br />❑ Q Vaulted ceilings shall be Insulated without compression to (Table 6.1) R30 (All options) <br />❑ Ei Skyllght wall Insulation Is Installed and equivalent to lho required wall R-valuos above. <br />❑ b vapor retarders shall be Installed toward the warm surface as represented below (502.1.6): <br />Soled one o lion lot floors, walls, aril appropriate ceilings: <br />Floors: Plywood W1 exterior glue O Poly (> 4 MR) 0 backed balls <br />Walls: Poly plastic (z 4 Mil) 0 face -stapled, backed balls PVA point <br />callings: S Not required whore vemllallon space averages >12" aboveinsulation. <br />U Face stapled backed balls O Poly piasllo (a 4 mil) , 0 PVA paint <br />❑ Heating system efficiency and sizing requirements shall be met as represented bolow: <br />❑ Maximum heating system output (150% of design heat bad) Is kW (S. 503.2.2) <br />❑ t@s Heating system requirements will Is met with the following system (S.503.4.1.1): <br />Mlr.f-e /A-,UMod01 If -Max. OUIPU✓`� KW 12oz Lam/ <br />Typp,f'G� <br />WSEClnsulaflon phase requirements: <br />Inspected by' Data--- <br />❑ © Envelope Floors shall be Insulated without compression, and with supports 24" O,C. to R-30 (All <br />Options, Table 6-1). <br />❑ ( Non -vaulted, altic ceilings shall be Insulated without compression to R38 (All Options, Table 6.1) <br />❑ 0Door systems shall tneel, 0 -Ui440 (Options I, III)' 0 U.20 (Options 11, IV, V. VI, VII, VIII, Table 6-1) <br />Door types are (1)%(3)__ <br />❑ Is Exposed loam Insulntlon shall comply as follows (S. 502.1.4.8): <br />r_] Prolecied wilh metal or plastic [lashing or equivalent material that extends below grade. <br />Page 5 of 6 <br />Page 5 of 6 <br />