Laserfiche WebLink
NC, -ON C L LM E -IS C) AttaChnmd C <br />r <br />CODE <br />Plans Examiner and Inspector Checklist <br />Permit No. 3-7 9 GO Address 9 14 - 9077/ S7 SW <br />Plane Examiner: Check, write in N/A, or fill in value on shaded boxes. <br />Inspector: Check off boxes at left as items are found to comply. <br />Compliance approach: (check one) ❑ Systems analysis ❑ Component performance LK Prescriptive path <br />Note: Some specifics on this form may not apply if <br />A) compliance approach is systems analysis or component performance; <br />B) compliance to minimum ventilation criteria is demonstrated through engineering calculations or performance testing. <br />FOUNDATION PHASE <br />❑ Slab: i-. p _I Exterior down to frosiline/slab bottom; or Interior 24' horizontal or vertical; or, If radiant, under entire slab <br />❑ Below grade exterior wall Insulation: CrrNJ�l._,...� (If Interior —see Insulation Phase) <br />❑ Radon mitigation: [NW If locally required, or crawispace venting <11V300ft2 of crawl, or vents Include an operable damper <br />FIIAMMG PHASE <br />❑ Framing: ; ✓iStandard j Ilntermedlete I Advanced <br />❑ Std air seal: solepVeubfir; rim JsVmud slll; window E door frms; peneiratlon-wire, plumb, duct, partition studs, flue, light fixtures <br />❑ Source specific exhaust fens: Size requirement — bath, laundry (50cfm); kitchen (100ctm) <br />❑ Whole house exhaust fan 660. . Intermittent system has manual 6 auto controls; Outdoor air supply req. for habitable mas. <br />or <br />❑ Integrated forced -air system outside air duct (with damper) allowing between .35 and .5 ACH <br />MSULATION PHASE <br />❑ <br />�{�_� <br />Well Insulation (above grads) <br />❑__] <br />Wall Insulation (below grade): Interior wall Insulation <br />❑ <br />�4 .��^" ....] <br />Floor Insulation <br />❑ <br />�{._�—] <br />Calling Insulation: Including salt hatch <br />❑ <br />iq._ N/A-] <br />Vaulted calling Insulation <br />❑ <br />Vapor retarders: <br />walls, floors, telling <br />❑ <br />Heating system type: ck1�For heatpumps, list size, HSPF, and COP <br />_...... _ I <br />FINAL PHASE <br />❑ Radon monitor on site: with Instructions and general information <br />❑ Thermostat: hent range, 55-75; AC range. 70-85; both, 55 65, Backup heat controls prevent simultaneous operation of primary Sys. <br />❑ Solid fuel appliances: glass or metal doors; direct comb. alr source, or 4' dla., damperod, Indirect Source for uncond. areas <br />❑ Fireplaces: 6' combustion air supply dul w/damper direct to firebox; tight fitting glass or metal doors. <br />❑ DHW heaters: NAECA label; separate power or gas shut-ofl; on R-10 pad If electric and In uncond. area or II on roncrete <br />❑ Mechanical ventilation ducts Insulated to RA: exhaust dues In unconditioned areas/supply ducts In conditioned areas <br />❑ h...W- A—_ I HVAC ducts,'plenum Insulation: ducts In unconditioned areas are Insulated and Joints are sealed <br />❑ Pipe Insulation: R-3 for hot and cold water piping In unconditioned areas (If service or recirculating, see Table 5-12) <br />❑ Ground cover: 6 mil black polyethylene/approved equal lapped 12" at Joints and extending to foundation well <br />