Laserfiche WebLink
C!• • •��rformk ce Path, • • 1 • a 4c/5b <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address Underwood Gartland - Building A Date 02/17/2015 <br /> Occupancy Group © Commercial 0 Group R For Building Department Use <br /> Change in occupancy or space conditioning O <br /> Note-Proposed UA may exceed Target UA by 10%per C101.4.4 and C101.4.5 <br /> Fenestration Area as%gross above-grade wall area 6.3% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 2.0% Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope <br /> elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:U-factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2. <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor, page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> Y R=26 ID:Rigid Above Deck 0.038 200544 7620.7 0.034 200544 6818.5 <br /> Q R= ID:(R-25.5 Interpolated Per Table 102.2.6) Above Deck Insulation U-0.034 <br /> R= ID: <br /> o R= ID: 0.031 <br /> m R= ID: Metal Building U-0.031 <br /> R= ID: <br /> R= ID: 0.021 <br /> Y R= ID: Single raft,attic, other U-0.021 <br /> O R= ID: <br /> R= ID: 0.055 <br /> 'l R= ID: Steel/metal frame U-0.055 <br /> a� <br /> R= ID: <br /> o -6 R= ID: 0.052 <br /> 0° R= ID: Metal Building U-0.052 <br /> N R= ID: <br /> R= ID: 0.054 <br /> o R= ID: Wood Frame,other U-0.054 <br /> o <br /> C, 3: R= ID: <br /> O <br /> R= ID:Exempt-Semi Heated Exception 0.104 70409 7322.5 0.104 70409 7322.5 <br /> in <br /> co R= ID: Mass Wall U-0.104 <br /> 2 R= ID: <br /> m R= ID: 0.104 <br /> m <br /> o 3: R= ID: Assumed to be Mass Wall U-0.104 <br /> m� <br /> m 2 R= ID: <br /> (D R= ID: <br /> W R= ID: 0.031 <br /> En R= ID: Mass Floor U-0.031 <br /> o R= ID: <br /> ami R= ID: 0.029 <br /> E R= ID: Joist/Framing U-0.029 <br /> ti R= ID: <br /> F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R= ID:No Insulation 0.730 2572 1877.6 0.540 2572 1388.9 <br /> r R= ID: Slab-On-Grade U-0.54 <br /> R= ID: <br /> R= ID: 0.550 <br /> a <br /> �n `) R= ID: Heated Slab-On-Grade U-0.55 <br /> = R= ID: <br /> `Proposed non-residential CMU walls meeting Table C402.1.2 Area UA Area UA <br /> Footnote D requirements can use the target Ll-value of 0.104 rather Page 1 <br /> than Appendix A values. Show footnote requirements in plans. Subtotal F273525 16821 273525 15530 <br /> Component Performance Compliance (UA) UA COMPLIES <br />