My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6101 ASSOCIATED BLVD BASE FILE 2017-06-05
>
Address Records
>
ASSOCIATED BLVD
>
6101
>
BASE FILE
>
6101 ASSOCIATED BLVD BASE FILE 2017-06-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2017 1:50:29 PM
Creation date
5/15/2017 10:33:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6101
Tenant Name
BASE FILE
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Zone=40f, ENV-SUM <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R' Revised Oct 2013 <br /> Project Info Project Address Underwood Gartland - Building A Date 2/17/2015 <br /> Compliance forms Associated Blvd @ Industry St For Building Department Use <br /> do not require a Everett WA <br /> password to use. Applicant Name: s <br /> Instructional and pp ynThesis PLLC (Randy Brown) <br /> calculating cells are Applicant Address: 12503 Bel-Red Road, suite 101, Bellevue, WA 98005 <br /> write-protected. <br /> Applicant Phone: 425-646-181e <br /> Project Description [2] New Building ❑Addition ❑Alteration ❑ Change of Occupancy/Conditioning <br /> Compliance Path ❑ Prescriptive p � Component Performance ❑Total Building Performance <br /> Selection required to enable forms. <br /> Occupancy Group U Commercial U Group R-R2&R3 over 3 stories and all R1 <br /> Selection required to enable forms. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration <br /> enter values for vertical fenestration, 5149. 0 — 82164 . 0 X 100 — 6.3% <br /> skylights,gross walls and roof on this <br /> ENV-SUM worksheet. Ifcomplying via <br /> the Component Performance path,enter Gross Exterior <br /> these values in the ENV-UA worksheet. Total Skylight divided by Roof Area times 100 equals %Skylight <br /> These values auto-fill from ENV-UA and <br /> are write-protected on ENV-SUM. 4160 . 0 _ 204704. 0 X 100 = 2 . 0% <br /> Vertical VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Fenestration Area <br /> Compliance <br /> Skylight Area SKYLIGHT AREA COMPLIES <br /> Vertical Fenestration 0 50%or more of the floor area is within a daylight zone per C402.3.1.1 <br /> Alternates O High Performance Fenestration U-factors and SHGC per C402.3.1.3 <br /> Compliance Method <br /> ❑Skylight area 3%or greater,VT-0.40 or greater <br /> Single Story Spaces ❑✓ Skylight effective aperture 1%or greater,provide calculation <br /> Requiring Skylights ❑Space eligible for exception _ - - <br /> Requires a minimum of 50%of floor area to be within a skylight daylight zone for specific <br /> space types.Refer to C402.3.2 for requirements. <br /> [� Project has semi-heated spaces as defined per C402.1.4 <br /> ❑✓ Applying wall exception to semi-heated spaces <br /> 1. Semi-heated spaces may comply under Prescriptive or Component Performance compliance <br /> Semi-Heated Spaces path. <br /> 2. Semi-heated spaces shall be documented separately from other conditioned spaces—provide <br /> separate compliance forms for each conditioned space type. <br /> 3.Envelope elements sepa a ing semi-heated from other conditioned spaces shall comply with <br /> exterior thermal envelope requirements. <br /> ❑ Walk-in Cooler ❑ Walk-in Freezer <br /> Refrigerated Spaces F1Refrigerated Warehouse Cooler ❑ Refrigerated Warehouse Freezer <br /> Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for <br /> these areas may be combined with non-refrigerated areas in the ENV-PRESCRIPTIVE form. Refer <br /> to C402.5 and C402.6 for requirements. <br /> Project includes more than one occupancy type and/or level of space conditioning.Multiple <br /> Mixed Occupancy and/or compliance forms may be required. Select all that apply to scope of project: <br /> Space Conditioning ❑ Commercial ❑ R2&R3 over 3 stories and all R1 Refrigerated Space <br /> ❑ Fully Conditioned ❑ Semi-Heated ❑ Low Energy' <br /> ❑ R2&R3-3 stories or less <br /> 'Low energy areas are exempt from all thermal envelope provisions and compliance forms for <br /> these areas are not required. Refer to C1101.5.2 for exemption. <br />
The URL can be used to link to this page
Your browser does not support the video tag.