6101 ASSOCIATED BLVD BASE FILE 2017-06-05
>
Address Records
>
ASSOCIATED BLVD
>
6101
>
BASE FILE
>
6101 ASSOCIATED BLVD BASE FILE 2017-06-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2017 1:50:29 PM
Creation date
5/15/2017 10:33:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6101
Tenant Name
BASE FILE
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SkylightTargetAdjustmentCalculations <br /> FS <br /> kylight area exceeds maximum allowed per Section C402.3.1,then Target Area Adjustment of all applicable envelope elements is required. This <br /> rksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information shown in this <br /> SKY=Skylight INR-Net roof excludes skylight) JGross Exterior Roof Area=SKY+NR <br /> Proposed Areas <br /> Skylight(Horizontal Fenestration)-> SKY= 2592.0 <br /> Opaque Roof -> NR= 198080.0 <br /> Gross Exterior Max Skylight% Maximum Skylight <br /> Roof Area (C402.3.1) Fenestration Area <br /> 200672.0 X 5.0% — 100 = 10033.6 <br /> Total Skylight Area Maximum Target Delta Skylight Area 0 Excess Skylight <br /> 2592.0 — 10033.6 = -7441.6 greater = <br /> -7441.6 <br /> Total Skylight Area Excess Skylight Target Skylight Area Total Skylight Area Target SL Multiplier Multiplier applied to all <br /> Proposed Skylight Areas <br /> 2592.0 — = 2592.0 — 2592.0 = 1.00 to calculate Target <br /> Skylight Area <br /> Net Roof Area Excess Skylight Target Net Roof Area Net Roof Target Net Roof Mult. <br /> 19 8 0 8 0.0 = 19 8 0 8 0.0 — 19 8 0 8 0.0 = 1.0 0 Multiplier applied to all <br /> + Proposed Opaque Roof <br /> Areas to calculate Target <br /> UA and SHGC x A Adjustments <br /> Skylight Proposed Area Target SL Mull. Target Area <br /> All 2592.0 X 1.00 = 2592.0 <br /> Roof Proposed Area Target Net Wall Mult. Target Area Target areas in shaded <br /> Insulation Above Deck 198080.0 X 1.0 0 = 19 8 0 8 0.0 boxes are applied to target <br /> areas on ENV-UA <br /> Metal Building X <br /> Attic/All Others X = <br /> Sum of target roof and <br /> Sum of Proposed 200672.0 Sum of Tar et 200672.0 skylight areas are <br /> p g calculated to equal the <br /> sum of proposed <br />