Laserfiche WebLink
Adjustment <br /> tions <br /> Vertical-Fenestration Target • • • <br /> If vertical fenestration area exceeds maximum allowed per Section C402.3.1,then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above rade <br /> Proposed Areas <br /> Vertical Fenestration-> VF= 5410.0 <br /> Opaque->I NW= 59587.0 1 DR= 5412.0 <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen.Area <br /> 70409.0 X 30.0a - 100 = 21122.7 <br /> I otal Vertical Delta Vertical Excess Vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 5410.0 - 21122.7 = -15712.7 II greater = <br /> -15712.7 <br /> Multiplier applied to all <br /> Total Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> 5410.0 - =15410.0 - 5410.0 = 1.00 calculate Target Vertical <br /> Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 59 587.0 + = 5 9 5 8 7.0 - 5 9 5 8 7.0 = 1.0 0 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> UA Adjustments calculate Target Above- <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame X = <br /> Metal frame,fixed 5179.0 X 1.00 = 5179.0 <br /> Metal frame,operable X = <br /> Metal frame,entrance door 231.0 X 1.00 = 231.0 Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame X <br /> target areas on ENV-UA <br /> = <br /> Metal Building = <br /> Wood!Other frame X = <br /> Mass 59587.0 X 1.00 = 59587.0 <br /> Sum of target above-grade <br /> Sum of Proposed 64997.0 Sum of Target 64997.0 wall and vertical <br /> fenestration areas are <br /> calculated to equal the <br /> SHGC x A Adjustments sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 2623.0 X 1.00 = 2623.0 <br /> 0.25 PF<0.5 X = <br /> PF>0.5 557.0 X 1.00 = 557.0 SHGC target areas in <br /> North Vertical Fenestration shaded boxes are applied <br /> to target areas on ENV- <br /> PF<0.2 1694.0 X 1.00 = 1694.0 SHGC <br /> 0.25 PF<0.5 X = <br /> PF 2! 536.0 X 1.00 = 536.0 <br />