Laserfiche WebLink
2-A:10-B:C shall be provided within 75 feet of travel on all floors of each building during <br /> construction and prior to occupancy. <br /> 10. Fire Alarm System-An approved automatic fire detection system shall be provided as <br /> required by City Ordinance No. 3021-07,Chapter 16.76, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval <br /> prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests,witnessed by a Fire Department Inspector,shall be performed,along <br /> with a certificate of completion,prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire <br /> alarm components,including basic wiring,may not commence before plans are <br /> approved by the Fire Department PIan Reviewer. Fire alarm drawings must be <br /> professionally rendered,in sufficient detail,and must be internally consistent. Riser <br /> diagrams must match installation plans and load calculations. Components must be listed <br /> and approved for use together. Changes to plans must include new drawings and <br /> calculations and must be approved by the Fire Department Plan Reviewer prior to <br /> installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Engineering&Public Services Department <br /> electrical permit must be present for any installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering& <br /> Public Services Department. Electrical inspections and approval are required prior to <br /> calling for acceptance tests. Call(42S) 257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing <br /> Fire Department inspection and testing and shall result in denial of occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy <br /> (NFPA 72, 2007 Edition,page 72-33). <br /> Call for design requirements per Authority Having Jurisdiction. <br /> Automatic smoke detection is required. <br /> 11. If applicable,for buildings with two or more floors,including sub-floors,the alarm system <br /> must call point-by-point reporting to an alarm center. <br /> 12. Fire Suppression (Sprinkler) System-An approved automatic suppression system shall be <br /> provided as required by City Ordinance No.3021-07,Chapter 16.76,of the Everett <br /> Municipal Code. The system must include'a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering&Public Services <br /> Department for examination and approval. Such plans shall include plans for the <br /> underground mains that will supply the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an <br /> NFPA 13,NFPA 13R,or NFPA 13D system depending upon several factors. Sprinkler <br /> installation shall not begin without an approved and stamped set of plans from the <br /> 18 <br />